4506-1xx
Diagnostics—E120
Power-On Self Test (POST) sequence
When you turn the printer on, it performs a POST. Check for correct POST functioning of the base printer by
observing the following process:
1.
All operator panel lights turn on momentarily.
2.
Lights then flash on and off sequentially.
3.
After the lights quit flashing, the Ready/Data light flashes until the fuser comes up to temperature (5–20
additional seconds, depending on the initial temperature of the fuser) and then stays on.
4.
The motor drive and fan come on.
5.
If there is a problem in the printer such as a paper jam, the panel lights indicate the problem. See
page 2-3
for more information.
6.
The printer cycles down into standby mode, and the Ready/Data light comes on solid.
Overview of the operator panel—E120
The printer operator panel has two buttons and two lights. Lights indicate the status of the printer. Buttons are
used to continue or cancel the current print job.
When the printer is turned on, both lights cycle as a self test is performed. Also, when the printer is reset, or
when a printer setting is changed in the menus, both lights cycle.
To learn more about the panel lights or to determine the status of the printer when lights are on,
patterns and error messages" on page
Continue
Cancel
•
Press and release Continue
•
Press and release Continue
•
Press and release Continue
•
Press and release Continue
•
Press and release Cancel
•
Press and hold Cancel
2-2
Service Manual
2-3.
Error
to resume printing.
twice quickly to display the secondary light sequence.
twice quickly to display the tertiary light sequences if present.
from the Ready state to print the menu settings page.
to cancel current job.
until all lights come on to reset.
see"Light
Ready / Data
2
"" on