Set Up and Set Down Adjustments
Set Up and Set Down Adjustments
Observe the Picture while making these adjustments. Normally, they do not have to be done.
Y-Drive Test Point
Under 2
nd
Buffer from top
All other DC Voltage adjustments should have already been made.
ADJUSTMENT LOCATION:
Center Right of the board.
A
VR601
VR401
B
ADJUSTMENT LOCATION:
Lower Center Right
of the board.
Set must be in "WHITE WASH"
SET-UP ADJUST:
1) Adjust VR601 and set the (A) portion of the signal to
match the waveform above. (155V p/p ± 5V)
SET-DN ADJUST:
2) Adjust VR401 and set the (B) time of the signal to match
the waveform above. (170uSec ± 5uSec)
52
August 2010
42PJ350