Safety Features - Harman P61A Installation And Operating Manual

Freestanding pellet stove
Table of Contents

Advertisement

Pellet fines may accumulate in the feeder body over a period
of time; therefore, a yearly inspection and cleaning of this
area must be performed.
To clean out fines:
1. Remove the rear cover panels Figure 35.
!
disconnect electrical power to the unit before
removing cover.
2. Remove wing nut and feeder cover on the side of the
feeder.
3. Use a vacuum cleaner to remove all fines.
4. Reinstall feed cover, wing nut, and rear cover panels.
note: Cover replacement is crutial for proper operation
of the stove. Make sure cover is sealed properly.
Pellet Fines may
build up in this
area
The low draft sensor which is a vacuum differential switch, monitors the negative pressure (draft) in the firebox through
a port on the rear of the feeder. Poor draft will result in an interruption of power to the feeder motor. Poor draft can be
caused by blockage in the exhaust, excessive build-up on the combustion blower fan blades, a failed combustion blower,
or a door or other opening to the firebox not sealed properly. The circuit board is monitoring the position of this switch.
During a feed cycle, if this switch were to open, the feed motor light on the control will stay illuminated with the power
being interrupted by the switch. If the switch opens when the cycle is at rest, the power light for the feed motor will not
illuminate. Be sure all doors, including the hopper lid, are securely closed when operating the appliance.
25
P61A Pellet Stove
cleaning the Feeder body
dANGeR

safety Features

5/16" Hex Head
Screws (2 on
each side)
Figure 35
5/16" Hex Head
Screws (2 on
each side)
Low Draft
Sensor
Air Intake
Flapper
3-90-05822R29_JR15_04/14