Williams 2696541 Owner's Operation And Installation Manual page 14

Infrared vent-free propane/lp gas
Table of Contents

Advertisement

OBSERVED PROBLEM
Burner(s)does not light after
ODS/pilot is lit.
Delayed ignition of burner(s).
Burner backfiring during combustion.
Burner plaque(s) does not glow.
Slight
smoke
or
odor
initial operation.
Heater produces clicking/ticking
noise just after burner is lit or
shut off.
White powder residue forming
within burner box or on adjacent
walls or furniture.
TROUBLESHOOTING
Continued
POSSIBLE CAUSE
1. Burner orifice is clogged.
2. Burner orifice diameter is too small.
3. Inlet gas pressure is too low.
1. Manifold pressure is too low.
2. Burner orifice is clogged.
1. Burner orifice is clogged or
damaged.
2. Burner is damaged.
3. Gas regulator is defective.
1. Plaque damaged.
2. Inlet gas pressure is too low.
3. Control knob set between locked
positions.
1. Residues from manufacturing
during
processes.
1. Metal is expanding while heating
or contracting while cooling.
1. When heated, the vapors
furniture polish, wax, carpet
cleaners,
powder residue.
from
etc. turn into white
14
REMEDY
1. Clean burner orifice (see Cleaning
and Maintenance, Page 12) or
replace burner orifice.
2. Replace burner orifice.
3. Contact
local
gas company.
1 . C o n t a c t l o c a l g a s c o m p a n y.
2. Clean burner (see Cleaning and
Maintenance, Page 12) or replace
burner orifice.
1. Clean burner orifice (see Cleaning
and Maintenance, Page 12) or
replace.
2. Contact Dealer or Williams
Furnace.
3. Replace gas regulator.
1. Replace burner.
2. Contact local gas company.
3. Turn control knob until it locks at
desired setting.
1. Problem will stop after a few hours
of operation.
1 . T h i s
i s
c o m m o n w i t h m o s t
heaters. If noise
contact qualified service person.
1.
Turn heater
off
furniture
polish, wax, carpet
cleaner, or similar products.
is
excessive,
when
using

Advertisement

Table of Contents
loading