Millivolt Appliance Checkout; Electronic Appliance Checkout - Superior Merit SLDVT-30NM Care And Operation Instructions Manual

Sldvt direct-vent gas fireplaces merit series
Table of Contents

Advertisement

SUPERIOR
Burner Air Shutter Adjustment Procedure
WARNINGS
• Air shutter adjustment should
only be performed by a quali-
fied professional service
technician.
• Ensure front glass panel are
in place and sealed during
adjustment.
CAUTIONS
• Soot will be produced if the
air shutter is closed too much.
Any damage due to carboning
resulting from improperly
setting the air shutter is not
covered under the warranty.
• The air shutter door and nearby
appliance surfaces are hot.
Exercise caution to avoid
injury while adjusting flame
appearance.
1. Locate adjustment rod and adjust air shutter
to the standard setting as shown in Figure
15 (adjustment rod is located in the lower
control compartment).
Note: Rotating the adjustment rod down
to decrease air and up to increase air.
2. Light appliance (follow lighting procedure on
lighting label in control compartment or see
the lighting instructions, Pages 21 and 22
in this manual).
3. Allow the burner to operate for at least 15 min-
utes while observing the flame continuously
to ensure that the proper flame appearance
has been achieved (see Figure 11 or 12). If
the following conditions are present, adjust
accordingly.
• If flame appears weak or sooty, adjust the
air shutter, incrementally, to a more open
position until the proper flame appearance
is achieved.
• If flame stays lowered blue, adjust the air
shutter, incrementally, to a more closed
position until the proper flame appearance
is achieved.
4. Leave the control knob (off/pilot/on) in the
ON position and the burner OFF/ON switch
OFF (and remote switches, if applicable).
5. When satisfied that the burner flame ap-
pearance is normal, close the lower control
compartment door (see Figures 11 and 12
on Page 15).
DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS
®
Burner Air Shutter Adjustment
Burner
Tube
Air Shutter
Adjustment Rod Down
(fully open air opening
position)
Main Burner Factory Air Shutter
Opening Setting - Inches (millimeter)
Model
SLDVT-30
SLDVT-35
SLDVT-40
SLDVT-45
Figure 15

Millivolt Appliance Checkout

The pilot flame should be steady, not lifting
or floating. Flame should be blue in color with
traces of orange at the outer edge.
The top 3/8" (10 mm) at the pilot generator
(thermopile) and the top 1/8" minimum (tip)
of the quick drop out thermocouple should be
engulfed in the pilot flame. The flame should
project 1" (25 mm) beyond the hood at all three
ports (see Figure 16).
To light the burner, refer to the lighting instruc-
tions on Page 21.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Adjustment Set-Screw
Adjustment
Rod Up
(closed min.
position)
Natural
Propane
Gas
Gas
Closed
3/32 (2.362)
Closed
3/32 (2.362)
Closed
3/32 (2.362)
Closed
3/32 (2.362)
Proper Pilot Flame Appearance
Pilot Hood
Thermocouple
Pilot
Nozzels
Thermopile
Figure 16: Millivolt Pilot

Electronic Appliance Checkout

To light the burner, refer to the lighting instruc-
tions on Page 23. Ensure the igniter lights the
pilot. The pilot flame should engulf the flame
sensor as shown in Figure 17.
Ignitor
Sensor
Figure 17: Electronic Pilot
Igniter Rod
3/8" Min.
(9 mm)
Pilot
Hood
17

Advertisement

Table of Contents
loading

Table of Contents