Appliance Operation; Millivolt Appliance Checkout; Electronic Appliance Checkout - Superior BBV-36RMN Installation Instructions Manual

Standard series 36" b-vented gas appliances
Table of Contents

Advertisement

When properly positioned, the rockwool will
unevenly cover approximately 85% of the gap
between the front burner and the grate front
face with no appreciable openings.
Carefully position the ceramic fiber log assem-
bly onto the burner, refer to the Homeowners
Care and Operation Instructions for detailed
log description and placement instructions.
Position the logs onto the pins of the burner,
with the cutouts fitted around the burner tube.
Ensure the rear log matches the cutout on its
bottom with the position of the pilot.

APPLIANCE OPERATION

Step 9. Checking the System – With gas line
installed run initial system checkout before
closing up the front of the unit. Follow the pilot
lighting instructions provided in the
Homeowner's Care and Operation Instructions.
For piezo ignitor location see Figure 18 (mil-
livolt appliances only).
Note: Instructions are also found on the pull out
labels attached to the gas control valve.
Piezo
Ignitor
SIT Valve
Piezo Ignitor
Honeywell Valve
Figure 18
When first lighting the appliance, it will take a
few minutes for the line to purge itself of air.
Once purging is complete, the pilot and burner
will light and operate as indicated in the in-
struction manual.
Subsequent lightings of the appliance will
not require such purging. Inspect the pilot
flame (remove logs, if necessary, handling
carefully).
Limit
Switch
Screws
Fireplace Front
Figure 19
MANUALLY-RESET BLOCKED FLUE SAFETY
SWITCH
This appliance is equipped with a manually-
reset blocked flue safety switch. Refer to
Figure 19 for its location. If during appliance
operation, the flame goes out (independently
of the burner on/off wall switch), it may be due
to the operation of this safety limit switch.
First allow the appliance to cool. Then reset
the safety switch by pushing the red reset
button on the back of the switch.
CAUTION: THE ELECTRONIC APPLIANCE
SHOULD BE TURNED OFF BEFORE REMOV-
ING THE LIMIT SWITCH.
To access the safety limit switch reset button,
remove the two screws. Pull out limit switch
with low voltage wires attached, push the reset
button, then reinstall the limit switch. At this
time turn the electronic appliance back on.
The appliance should then relight and remain
lit. If this does not occur, turn off the appli-
ance and call a qualified service technician.

Millivolt Appliance Checkout

The pilot flame should be steady, not lifting or
floating. Flame should be blue in color with
traces of orange at the outer edge.
The top " (9 mm) at the pilot generator (thermo-
pile) should be engulfed in the pilot flame. The
flame should project 1" (25 mm) beyond the
hood at all three ports (Figure 20 ) .
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Manual Reset Limit Switch
Left Side Refractory Panel
Hood
Pilot
Nozzels
Figure 20
Replace logs if removed for pilot inspection.
To light the burner; turn "ON" the remote wall
switch and rotate the gas valve control knob
counterclockwise to the "ON" position ("ON"
will be to the left hand side of the valve).

Electronic Appliance Checkout

To light the burner, turn 'ON' the optional
remote wall switch and turn the gas control
switch to the "ON" position. Ensure the ignitor
lights the pilot. The pilot flame should engulf
the flame rod as shown in Figure 21.
Lintel
Extention
Ignitor Rod
" Min
(9 mm)
9