Test Mode; Electrical Adjustment - Sony STR-DA333ES Service Manual

Hide thumbs Also See for STR-DA333ES:
Table of Contents

Advertisement

TEST MODE

FLUORESCENT INDICATOR TUBE TEST MODE
* All fluorescent segments are tested. When this test is activated,
all segments turn on at the same time, then each segment turns on
one after another.
Procedure:
While depressing the FUNCTION MODE button and the SOUND
FIELD MODE button simultaneously, press the 1/u button to
turn on the main power. All segments turn on at the same time, then
each segment turns on one after another.
When the CURSOR MODE button, B , V , v , or b is pressed,
the indication advances in the following order: All segments on,
Bridge 1, Bridge 2, All segments off.
All segments on
Bridge 1
Bridge 2
All segments off
FACTORY SET MODE
* All preset contents are reset to the default setting.
Procedure:
While depressing the FUNCTION MODE button and the SOUND
FIELD GENRE button simultaneously, press the 1/u button to
turn on the main power. The message FACTORY SET appears and
the present contents are reset to the default values.
ALL CLEAR MODE
* All preset contents are cleared when this mode is activated. Use
this mode before returning the product to clients upon completion
of repair.
Procedure:
While depressing the SOUND FIELD GENRE button and the
SOUND FIELD ON/OFF buttons simultaneously, press the 1/u
button to turn on the main power. The message "ALL CLEAR!"
appears and the preset data is cleared.
SECTION 3
SOUND FIELD CLEAR MODE
* The preset sound field is cleared when this mode is activated.
Use this mode before returning the product to clients upon comple-
tion of repair.
Procedure:
While depressing the SOUND FIELD ON/OFF button, press the
1/u button to turn on the main power. The message "SURR
CLEAR!" appears and initialization is performed.
DSP TEST MODE
Procedure:
While depressing the FUNCTION MODE button and the EQUAL-
IZER buttons simultaneously, press the 1/u button to turn on the
main power. The message "DSP NO ERROR" or "DSP ERROR".
When "DSP NO ERROR" is displayed, a 1 kHz signal is output to
all channels.
When the B , V , v , or b button is pressed while "DSP NO
ERROR" is displayed, the message "DSP TEST MODE" appears.
In this mode, the input signal that is selected by the FUNCTION
knob is distributed to each speaker.
Speaker
CENTER
REAR L
REAR R
FRONT L
Signal
L
L
R
DTS MODE
* Some DTS sounds will be distorted even when the volume is low-
ered. In this case, set the attenuator to ON according to the fol-
lowing procedure and reduce the overall level of the sound.
Procedure:
While pressing the B button and b button simultaneously, press
the 1/u button to turn ON the power. The message "ATTENU-
ATE OFF" or "ATTENUATE ON" message appears.
– 9 –
IDLING CURRENT ADJUSTMENT
Measuring Instrument:
Adjustment Procedure:
Channel
Test point
Adjustment element
TP501
FRONT L
RV501
FRONT R
TP551
RV551
CENTER
TP601
RV601
REAR L
TP701
RV701
REAR R
TP751
RV751
Adjustment Location:
FRONT R
L
R
SECTION 4

ELECTRICAL ADJUSTMENT

Digital voltmeter
Adjust the respective adjustment elements so that the voltage (absolute value) across the corresponding
testpoints satisfies the specification.
Specification
6mV
MAIN BOARD
TP501
TP601
RV501
S. AMP BOARD
RV751
TP701
TP751
– 10 –
STR-DA333ES/DA555ES
RV601
RV551
TP551
RV701

Hide quick links: