4. CENTRALIZED REMOTE CONTROLLER
Allows individual or combined control of up to 16 units.
Part No.
4-1 Dimensions
E N G A G E D
G R O U P
1 2 3 4 5 6 7 8 9 10
A C T I V E B Y P A S S
D U A L C E N T R A L
4-2 Names and Functions
"ENGAGED" indicator
When this indicator is lit, transmission is in
progress and all switches are inoperative.
DUAL/CENTRAL switch
This change-over switch governs the oper-
ation of the accessory remote controller.
"DUAL"
Instructions from both the accessory
remote controller and the centralized
remote controller are valid. (Priority given
to the last instruction received.)
"CENTRAL"
ON/OFF switching by the accessory
remote controller is invalidated. Operation
is controlled by the centralized remote con-
troller only.
Initial setting is "DUAL".
LCD Matrix Display
This display indicates the operational sta-
tus of all connected units either by steady
lighting or by flashing.
Independent "DUAL / CENTRAL" and "ACTIVE / BYPASS" setting of all the groups is possible. When the power supply to the
centralized remote controller is cut due to power failure, all settings will return to original "DUAL" and "BYPASS".
POWER
ON/OFF
G R O U P
BACK
AHEAD
S E L E C T I O N
P R O G R A M
ACTIVE
T I M E R
BYPASS
C O N T R O L L E R
DUAL
O P E R A T I O N
CENTRAL
MITSUBISHI ELECTRIC
1 1 7
G R O U P
1 2 3 4 5 6 7 8 9 10
A C T I V E B Y P A S S
D U A L C E N T R A L
PAC-805RC
1 2
POWER
E N G A G E D
ON/OFF
G R O U P
AHEAD
BACK
S E L E C T I O N
P R O G R A M
ACTIVE
T I M E R
BYPASS
C O N T R O L L E R
DUAL
CENTRAL
O P E R A T I O N
MITSUBISHI ELECTRIC
43
1 1 3
5 6 . 3
1 1
2 3 . 5
POWER
E N G A G E D
ON/OFF
G R O U P
1 2 3 4 5 6 7 8 9 10
G R O U P
AHEAD
BACK
S E L E C T I O N
P R O G R A M
ACTIVE
A C T I V E B Y P A S S
T I M E R
BYPASS
C O N T R O L L E R
DUAL
D U A L C E N T R A L
O P E R A T I O N
CENTRAL
10 9 8 7 6 5 4 3 2 1
POWER ON/OFF switch
Operation ON/OFF switch.
BACK
AHEAD buttons
These buttons are used to designate
the attached unit(s). (They designate
the unit to be centrally controlled.)
When group "00" is designated; col-
lective ON/OFF instruction is sent to all
units.
When group "01"-"16" is designated;
ON/OFF instruction is sent only to the
designated units.
ACTIVE/BYPASS switch
This is a change-over switch for the
program timer.
Use "BYPASS" when a program timer
is not connected.
Unit : mm