2-8 Wireless remote controller pair number setting operation
PK-2.5FLD, PK-2.5FLD
1
PK-3FLD,
PK-3FLD
1
PK-4FLSD, PK-4FLSD
1
After refiling batteries.
Press the reset button.
Nrm Set
PK-2.5FLD
2
PK-3FLD
2

PK-4FLSD

2
MODEL SELECT
ON/OFF
TEMP
AUTO STOP
FAN
MODE
AUTO START
VANE
CHECK LOUVER
TEST RUN
SET
RESET
CLOCK
1,4
Switches are located on the indoor unit PC board and inside the remote con-
troller as shown.
• Setting the SW1 (PC board inside indoor unit)
Sub-switches 7 or 8 of SW1 can be used as foolws to assign a pair No.
Pair Number
• The pair No. SW of the remote controller has been set to ‹‹0›› at the time of
ship-ment.
Reset
Note:
Make sure that the pair No. A A of the remote controller matches that of
the indoor unit PC board.
A
1 Turn on the main power to the unit.
2 Press the SET button with the point of a ball-point pen or the like.
Start this operation from the status of remote controller display turned off.
MODEL SELECT
3 Press the
A Pair No. "0" blinks.
4 Press the temp
A
5 Press the SET button with the point of a ball-point pen or the like.
Set pair number is lighted for three seconds then turned off.
Model No.
A Pair No. of wireless
4
h
min
5
SW1
ON
0
OFF
1 2 3 4 5 6
7 8
ON
1
OFF
1 2 3 4 5 6
7 8
blinks and Model No. is lighted.
min
button twice continuously.
button to set the pair number you want to set.
Indoor PC board
remote controller
ON
0
OFF
1 2 3 4 5 6
ON
1
OFF
1 2 3 4 5 6
ON
2
OFF
1 2 3 4 5 6
ON
3~9
OFF
1 2 3 4 5 6
28
Pair Number
SW1
ON
2
OFF
1 2 3 4 5 6
ON
3
OFF
1 2 3 4 5 6
< SW1 >
7 8
7 8
7 8
7 8
7 8
7 8