Superior VRT43STWS Installation And Operation Instructions Manual page 9

Unvented (vent-free) universal firebox
Table of Contents

Advertisement

CAUTION: Log appliances
installed in this firebox create
warm air currents. These currents
move heat to wall surfaces next
to firebox. Installing firebox next
to vinyl or cloth wall coverings or
operating firebox where impuri-
ties (such as, but not limited to, to-
bacco smoke, aromatic candles,
cleaning fluids, oil or kerosene
lamps, etc.) in the air exist, may
discolor walls or cause odors.
IMPORTANT: Vent-free gas log appliances
add moisture to the air. Although this is benefi-
cial, installing firebox in rooms without enough
ventilation air may cause mildew to form from
too much moisture. See Air for Combustion
and Ventilation, page 6.
IMPORTANT: Make sure the firebox is level.
If firebox is not level, log set will not work
properly.
Note: Your firebox is designed to be used in
zero clearance installations. Wall or framing
material can be placed against any exte-
rior surface on the rear, sides or top of your
firebox, except where standoff spacers are
integrally attached. If standoff spacers are
attached to your firebox, these spacers can
be placed directly against wall or framing
materials.
Use dimensions shown for rough openings
to create the easiest installation (see Built-In
Firebox Installation, page 9).
INSTALLATION CLEARANCES
WARNING: Maintain the
minimum clearances. If you can,
provide greater clearances from
floor, ceiling and adjoining wall.
Carefully follow the instructions below. This
will ensure safe installation.
Minimum Wall and Ceiling Clearances
A. Clearances from side of firebox opening
to any combustible wall should not be less
than 8".
B. Clearances from top of firebox opening to
the ceiling should not be less than 42".
126703-01A
INSTALLATION
Continued
www.SuperiorFireplaces.US.com
C. When firebox is installed on carpeting
or other combustible material, other
than wood flooring, the firebox should
be installed on a metal or wood panel
extending the full width and depth of the
enclosure.
D. Clearances from bottom of firebox to the
floor is 0".
CAUTION: Do not install
the firebox directly on carpet
or vinyl.
CAUTION: Use only the clear-
ances specified in this manual or
on the firebox rating plate.
Minimum clearances to combustibles are:
• Sides of outer casing
• Drywall to sides and top of
front face
• Ceiling to opening
• Floor (see Minimum Wall
and Ceiling Clearances, note C)
• Perpendicular walls
Right and Left
• Distance to Facing Walls
See Figures 5 and 6.
0" Min. Clearance to
Ceiling
Upper Frame/Wallboard
4" Min.
Figure 5 - Minimum Clearance Front View
1/2" Min. Clearance
to Combustibles
22
/
"
3
4
4" Min. from the Perpendicular
Side Wall to the Edge of Facial
Figure 6 - Minimum Clearance - Top View
0" min.
0" min.
42' min.
0" min.
4' min.
36" min.
42" Min.
0" to Wood
Floor
44
/
"
1
4
24"
9