Points to notice for Inspection & Adjustment of Flash
When the adjustment item 4. (Inspection & adjustment of flash) is made, be careful of the following:
*Be sure to make the adjustment in a dark place (e.g. photo darkroom, etc) without influence of outside light.
*If there is some reflector (e.g. desk, etc) in front of SB, it may affect the accuracy.
Therefore, be sure to align both the edges of the communication tool (J15405) and stand (desk, etc) as shown below.
Flash meter
Standard reflection paper
Align the edges of the communication tool
(J15405) and stand (desk, etc).
1m
- A21 ・ SB-800 -
J15405
FSA03501-R.3613.A
PC