  Xe-tube
・Cut out the heat contraction tube on the + side of Xe-tube with nipper, etc, and remove the solder of the pink
wire.
・On the trigger coil side, remove the solder of the trigger lead wire (Gray) that connects the - side of Xe-tube.
・Detach the Xe-tube in the direction indicated by the arrow.
・Cut out the heat contraction tube on the -side of Xe tube with nipper, etc, and remove the solder of the white
wire.
Pink
lead solder
  Fiber ②
・Remove the tape.
・Detach the fiber in the direction indicated
by the arrow.
Trigger coil
Xe tube + side
Attached with glue
- D8 ・ SB-800 -
FSA03501-R.3613.A
Gray: Trigger lead wire
lead-free solder
Xe tube - side
Xe-tube
Tape