Pre-Installation Preparation - Comfort Glow CHDV32NR Owner's Operation And Installation Manual

Direct-vent
Table of Contents

Advertisement

PRODUCT FEATURES
Continued
• This fireplace does not require electricity
to operate.
• Only the blower requires electricity if in-
stalled and if you plan to install the blower
at a later date, do not forget to wire the
outlet at the bottom of the fireplace when
framing.
• A piezo ignitor and ceramic electrode cre-
ate spark to ignite the pilot light. It does not
require any matches, batteries or any other
sources of ignition to light the pilot.
• Each time you turn on your fireplace, you
may notice some amount of condensation
on the inside of the fireplace glass. This
is normal and will disappear after 10-20
minutes of operation.
• Your direct-vent gas fireplace system
(fireplace and venting) is a balanced and
sealed gas operating unit. It requires ap-
proximately 10-20 minutes of operating
time before the flame pattern stabilizes.
PRE-INSTALLATION
PREPARATION
LOCATION AND SpACE
REqUIREMENTS
Determine the safest and most efficient loca-
tion for your FMI PRODUCTS, LLC direct-vent
fireplace. Make sure that rafters and wall
studs are not in the way of the venting system.
Choose a location where the heat output is
not affected by drafts, air conditioning ducts,
windows or doors. Figure 2 shows some com-
mon locations. Be aware of all restrictions and
precautions before deciding the exact location
for your fireplace and termination cap.
When deciding the location of your fireplace,
follow these rules:
• Do not connect this fireplace venting to a
chimney flue serving a separate solid-fuel
burning fireplace or appliance.
• Due to high temperatures, do not locate this
fireplace in high traffic areas, windy or drafty
areas or near furniture or draperies.
• Proper clearances must be maintained.
• If your fireplace is to be installed directly on
carpeting, vinyl tile or any combustible ma-
terial other than wood, it must be installed
on a metal or wood panel extending the
full width and depth of the fireplace. See
Figure 3.
111986-01G
• Your fireplace is designed to be used in
zero clearance installations. Wall or framing
material can be placed directly against any
exterior surface on the back, sides or top of
your fireplace, except where standoff spacers
are integrally attached. If standoff spacers
are attached to your fireplace, these spacers
can be placed directly against wall or framing
material. See framing details on page 6.
• If you plan on installing a television or
entertainment center recessed above
your fireplace, it is recommended that you
maintain a minimum 18" above top of louver
opening.
• When locating termination cap, it is impor-
tant to observe the minimum clearances
shown in Figure 7, page 7.
• If recessing into a wall, you can avoid extra
framing by positioning your fireplace against
an already existing framing member.
• Do not recess termination cap into a wall
or siding.
• You may paint the termination cap with 450º
F (232º C) heat-resistant paint to coordinate
with the exterior finish.
• There must not be any obstruction such
as bushes, garden sheds, fences, decks
or utility buildings within 24" from the front
of the termination cap.
• Do not locate termination cap where exces-
sive snow or ice build up may occur. Be sure
to clear vent termination area after snow falls
to prevent accidental blockage of venting
system. When using snow blowers, do not
direct snow towards vent termination area.
Figure 2 - Common Fireplace Locations
D
16
Figure 3 - Fireplace Bottom Dimensions
www.fmiproducts.com
Flush with a wall
Through exterior wall
enclosed in a chase
22
RW
/
"
5
8
34
FW
Corner
installation
/
"
1
2
/
"
3
8
5