TCONT800AS11AA Touch Screen
Programmable Comfort Control
18-HD25D18-3
APPLICATION
The TCONT800AS11AA Programmable Comfort Control provides electronic control of 24 Vac heating and cooling
systems. See Table 1 for a general description.
Power Method
24 Vac common wire
RECYCLE NOTICE
If this control is replacing a control that contains
mercury in a sealed tube, do not place your old
control in the trash. Dispose of properly.
Contact your local waste management authority
for instructions regarding recycling and the
proper disposal of the old control.
INSTALLATION
When Installing this Product...
1. Read these instructions carefully. Failure to follow
the instructions can damage the product or cause
a hazardous condition.
2. Installer must be a trained, experienced service
technician.
3. After completing installation, use these instructions
to check out the product operation.

Selecting Location

Install the comfort control about 5 ft. (1.5m) above the
floor in an area with good air circulation at average
temperature. See Fig. 1.
U.S. Patent No. #6595430, D509151 and Other Patents Pending
This thermostat contains a Lithium battery which may contain
Perchlorate material. Due to State Law in California, the following
statement is required:
Perchlorate Material—special handling may apply,
See www.dtsc.ca.gov/hazardouswaste/perchlorate
Table 1. TCONT800AS11AA Comfort Control Description.
Changeover
System Selection
Automatic or
Heat-Off-Cool-Auto
manual
selectable
INSTALLATION INSTRUCTIONS
Fan Selection
On-Auto-Circ
NO
NO
Fig. 1. Selecting comfort control location.
Do not install the comfort control where it can be
affected by:
— Drafts or dead spots behind doors and in corners.
— Hot or cold air from ducts.
— Radiant heat from sun or appliances.
— Concealed pipes and chimneys.
— Unheated (uncooled) areas such as an outside wall
behind the comfort control.
Comments
System and Fan selection vary
based on system type
NO
YES
5 FEET
[1.5 METERS]
69-1787-03
M19925

Advertisement

Table of Contents
loading

Summary of Contents for Trane TCONT800AS11AA

  • Page 1: Selecting Location

    TCONT800AS11AA Touch Screen Programmable Comfort Control 18-HD25D18-3 INSTALLATION INSTRUCTIONS APPLICATION The TCONT800AS11AA Programmable Comfort Control provides electronic control of 24 Vac heating and cooling systems. See Table 1 for a general description. Table 1. TCONT800AS11AA Comfort Control Description. Power Method Changeover...
  • Page 2 TCONT800AS11AA TOUCH SCREEN PROGRAMMABLE COMFORT CONTROL Installing Wallplate pump) in Fig. 3. 2. Loosen the screws for the appropriate system type selected; see Table 2. Insert wires in the terminal block under the loosened screw. See Fig. 4. CAUTION 3. Securely tighten each screw.
  • Page 3 TCONT800AS11AA TOUCH SCREEN PROGRAMMABLE COMFORT CONTROL HEAT/COOL HEAT/COOL HANDLER FURNACE OIL BURNER PRIMARY INDOOR INDOOR OUTDOOR OUTDOOR COOLING UNIT COOLING UNIT O.D. SECTION O.D. SECTION (SINGLE STAGE) (SINGLE STAGE) (3 PH TO POWER SUPPLY (3 PH ONLY) TO POWER SUPPLY...
  • Page 4 TCONT800AS11AA TOUCH SCREEN PROGRAMMABLE COMFORT CONTROL Powering the Comfort Control The comfort control can be powered with 24 Vac. WALL 24 Vac Common Power (Recommended) Wire the common side of the transformer to the B screw of the comfort control wallplate. When installing in a single transformer system, keep the jumper wire between the R and Rc screws.
  • Page 5: Operation

    TCONT800AS11AA TOUCH SCREEN PROGRAMMABLE COMFORT CONTROL OPERATION SET CURRENT DAY SET MONTH System and Fan Settings The System default setting is Heat and the Fan default setting is Auto. SAT A A T SYSTEM Settings Heat: controls heating system. Off: both heating and cooling are off.
  • Page 6: Installer Setup

    TCONT800AS11AA TOUCH SCREEN PROGRAMMABLE COMFORT CONTROL INSTALLER SETUP The comfort control works with many different system 4. Release the two blank keys when the screen on the types. To operate correctly, the comfort control must be comfort control matches the screen below.
  • Page 7 TCONT800AS11AA TOUCH SCREEN PROGRAMMABLE COMFORT CONTROL IMPORTANT The Installer Setup Menu (Table 4) shows all available options. These options customize themselves as you make selections to Installer Setup. So not all Installer Setup Selections are shown or are available to change.
  • Page 8 TCONT800AS11AA TOUCH SCREEN PROGRAMMABLE COMFORT CONTROL Table 4. Installer Setup Menu. (Continued) Factory Setting Other Choices Installer Setup Select Number Option Description Options Description Comments Continuous 0280 Backlight not on Backlight is on continuously Option is always Backlight continuously. (comfort control must have a shown;...
  • Page 9 TCONT800AS11AA TOUCH SCREEN PROGRAMMABLE COMFORT CONTROL Table 4. Installer Setup Menu. (Continued) Factory Setting Other Choices Installer Setup Select Number Option Description Options Description Comments Number of 0540 Four periods Two periods available (Wake Not shown if non- Periods available (Wake,...
  • Page 10 TCONT800AS11AA TOUCH SCREEN PROGRAMMABLE COMFORT CONTROL Table 4. Installer Setup Menu. (Continued) Factory Setting Other Choices Installer Setup Select Number Option Description Options Description Comments Temperature 0680 Standard 1, 3 1—less aggressive Applies to Control in temperature control temperature control (could...
  • Page 11: System Checkout

    TCONT800AS11AA TOUCH SCREEN PROGRAMMABLE COMFORT CONTROL SYSTEM CHECKOUT ADVANCED FEATURES Installer System Test Outdoor or Indoor Temperature Sensor The Installer System Test mode is used to test the HVAC For accuracy, the initial reading of the indoor or outdoor system(s). See Table 5. While in System Test mode, temperature sensor requires fives minutes to stabilize.
  • Page 12 TCONT800AS11AA TOUCH SCREEN PROGRAMMABLE COMFORT CONTROL TROUBLESHOOTING (SEE TABLE 6) Table 6. Troubleshooting. Symptom Possible Cause Action Display does not come on. Comfort control is not Check for 24 Vac between B and Rc. being powered. Temperature settings do not The upper or lower Check temperature setpoints.

This manual is also suitable for:

18-hd25d18-3

Table of Contents