Use Of The Remote Control - Carrier 42PQV Owner's Manual

Split system “hi-wall” indoor unit
Hide thumbs Also See for 42PQV:
Table of Contents

Advertisement

42PQV

Use of the remote control

Start / Stop
(button B)
When the air conditioner is not in operation, the remote control
readout will display the time of day only (in case other symbols are
lit, turn control off by pressing button
Press button
to start the air conditioner.
All selected and memorized functions will light up and appear; the
unit will operate according to the functions selected.
Press button
to stop the air conditioner.
All indicators on the unit will go out, and the control will display
only the current time.
If the unit does not stop, turn the control on (by pressing button
) and repeat the operation.
If button
(air conditioner starting) is pressed too soon after a
stop, the compressor will not start for 3minutes due to the
inherent protection against frequent compressor cycling.
The unit will only emit a "beep", when the signals are received
correctly.
Selection of the operating mode
(button A)
With this button the operating mode of the air conditioner can be
selected.
By repeatedly pressing this button the available modes will be
selected in sequence.
The choosen mode is shown as follows, while the unit will
acknowledge signal receipt with a confirming beep.
Indicated Symbol
Ventilation (fan only).
Heating.
Automatic.
Cooling with dehumidification.
Dehumidification only.
Temperature setting
UP
(button C)
DOWN
(button D)
Pressing the UP
and DOWN
decrease the temperature from the previously set value.
The unit will confirm signal receipt with a beep, and the value of the
set temperature on the display will change accordingly.
The temperature can be set between 17°C (63°F) and 32°C (90°F)
at 1 degree intervals.
In cooling mode, if the temperature selected is higher than the
room temperature the unit will not start; the same applies for the
heating mode, if the selected temperature is lower than the room
temperature.
Selecting direction of air flow louvre
(button H)
The air flow direction can be adjusted to optimize air distribution in
the room.
Press button
repeatedly to choose one of the following louvre
positions:
).
buttons will increase or
Symbol on display
Air direction will be set automatically.
Louvre will be set to the preset position according to the
operation mode.
6 positions can be chosen.
The louvre can be set to one of 6 different air
flow directions.
The louvre will continuously swing up and down. "Swing"
always assures optimal even air distribution in the room.
In the COOL DRY and FAN mode, the louvre will swing in the cooling
range. In the HEAT mode, the louvre will swing in the heating range.
Note:
Always use the remote control to adjust the louvre position,
otherwise abnormal operation may occur. If you manually adjust the
louvre out of its range, please turn the unit off and then on again.
Left and right control
If you want to adjust the direction of the discharge air to the left or
right, adjust the vertical guide vane with the handle after opening
the louvre.
Note:
• Please do not set the louvre to position
because this position minimises air circulation resulting in uneven
room temperature.
• Do not adjust the louvre by hand during SWING operation
because it may damage the air swing mechanism.
• If you want maximum cooling or heating capacity, please set
louvre to position
.
Selecting the fan speed
(button E)
The fan speed can be selected by pressing button
Indicated symbol
Low speed
(for night operation)
Medium speed
High speed
(at start-up, to reach temperature)
Automatic (fan speed will automatically switch to the value
required for optimum comfort).
Handle
for a long time,
.
7