E-4
PROBLEMS
(SYMPTOMS)
Thermal Protection Indicator light is
on.
Machine does not have maximum
output
Machine will not shut off.
Variable or sluggish welding arc.
Digital meters do not light
- or -
Digital meter display is incorrect.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
POSSIBLE AREAS OF
MISADJUSTMENTS
PROBLEMS
1. Thermostat circuit has opened.
2. Faulty Control PC Board.
1. Faulty Control PC Board.
2. Voltage Adjust potentiometer
defective.
3. Voltage Adjust potentiometer
leads open.
1. Defective power switch.
1. Poor work or electrode
connection.
2. Welding leads too small.
3. Welding current or voltage
too low.
4. Defective SCR bridge.
1. Faulty Meter PC board.
2. Faulty Control PC Board.
If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.
CAUTION
CV-300
RECOMMENDED
COURSE OF ACTION
E-4