Ferroli DOMIcondens HE 26 C Instructions For Use, Installation And Maintenance page 3

Hide thumbs Also See for DOMIcondens HE 26 C:
Table of Contents

Advertisement

DOMIcondens HE 26 C
EN
1. GENERAL INSTRUCTIONS
Carefully read the instructions contained in this instruction booklet.
After boiler installation, inform the user regarding its operation and give him this manual, which is an integral
and essential part of the product and must be kept with care for future reference.
Installation and maintenance must be carried out by professionally qualified personnel, according to current
regulations and the manufacturer's instructions. Do not carry out any operation on the sealed control parts.
Incorrect installation or inadequate maintenance can result in damage or injury. The Manufacturer declines
any liability for damage due to errors in installation and use or failure to follow the instructions.
Before carrying out any cleaning or maintenance operation, disconnect the unit from the power supply using
the system switch and/or the special cut-off devices.
In case of a fault and/or poor operation, deactivate the unit and do not attempt to repair it or directly intervene.
Contact professionally qualified personnel. Repair/replacement of the products must only be carried out by
professionally qualified using original spare parts. Failure to comply with the above could affect the safety of
the unit.
This unit must only be used for its intended purpose. Any other use is considered improper and therefore
dangerous.
The packing materials are potentially hazardous and must not be left within the reach of children.
The images given in this manual are a simplified representation of the product. In this representation there
may be slight and insignificant differences with respect to the product supplied.
2. OPERATING INSTRUCTIONS
2.1 Introduction
Dear Customer,
DOMIcondens HE 26 C is a high-efficiency sealed chamber condensing heat genera-
tor for heating and hot water production running on natural gas or LPG, and equipped
with a microprocessor control system.
2.2 Control panel
Panel
1
2
8
5
11
12
14
3
4
fig. 1 - Control panel
Panel key fig. 1
1
DHW temperature setting decrease button
2
DHW temperature setting increase button
3
Heating system temperature setting decrease button
4
Heating system temperature setting increase button
5
Display
6
"Sliding Temperature" Menu - Summer/Winter mode selection - Reset button
7
Unit On/Off - Economy/Comfort mode selection button
8
DHW symbol
9
DHW mode
10
Summer mode
11
Multifunction
12
Eco (Economy) mode
13
Heating
14
Heating symbol
15
Burner lit and actual power level (flashing during combustion fault function)
16
Service Tool connection
17
Arrangement for clock
Indication during operation
Heating
A heating demand (generated by the Room Thermostat or Remote Timer Control) is in-
dicated by flashing of the hot air above the radiator on the display.
The display (detail 11 - fig. 1) shows the actual heating delivery temperature and, during
heating standby time, the message "d2".
Domestic hot water (DHW)
A DHW demand (generated by drawing domestic hot water) is indicated by flashing of
the hot water under the tap on the display.
The display (detail 11 - fig. 1) shows the actual DHW outlet temperature and, during
DHW standby time, the message "d1".
Comfort
A Comfort demand (reinstatement of temperature inside the boiler) is indicated by flash-
ing of the water under the tap on the display. The display (detail 11 - fig. 1) shows the
actual temperature of the water in the boiler.
Fault
In case of a fault (see cap. 4.4) the display (detail 11 - fig. 1) shows the fault code and,
during safety standby times, the messages "d3" and "d4".
3540Z850
9
10
15
7
eco
comfort
reset
13
16
6
cod. 3540Z850 - 12/2010 (Rev. 00)
2.3 Lighting and turning off
Connection to the power supply
During the first 5 seconds the display will also show the card software release.
Open the gas cock ahead of the boiler.
The boiler is now ready to function automatically whenever domestic hot water is drawn or in
case of a heating demand (generated by Room Thermostat or Remote Temperature Control).
Turning the boiler off and on
Press the on/off button (detail 7 - fig. 1) for 5 seconds.
When the boiler is turned off, the PCB is still powered. Domestic hot water and heating are disa-
bled. The antifreeze system remains activated. To relight the boiler, press the on/off button (detail
7 fig. 1) again for 5 seconds.
The boiler will be immediately ready to work whenever domestic hot water is drawn or in case of a
heating demand (generated by the Room Thermostat or the Remote Timer control).
17
B
The antifreeze system does not work when the power and/or gas to the unit are turned
off. To avoid damage caused by freezing during long idle periods in winter, it is advisable
to drain all water from the boiler, DHW circuit and system; or drain just the DHW circuit
and add a suitable antifreeze to the heating system, complying with that prescribed
insec. 3.3.
2.4 Adjustments
Summer/Winter Switchover
Press the summer/winter button (detail 6 - fig. 1) for 2 seconds.
The display activates the Summer symbol (detail 10 - fig. 1): the boiler will only deliver
domestic hot water. The antifreeze system remains activated.
To deactivate the Summer mode, press the summer/winter button (detail 6 - fig. 1)
again for 2 seconds.
Heating temperature setting
Use the heating buttons (details 3 and 4 - fig. 1) to adjust the temperature from a min. of
30°C to a max. of 85°C; it is advisable not to operate the boiler below 45°C.
DHW temperature adjustment
Use the DHW buttons (details 1 and 2 - fig. 1) to adjust the temperature from a min. of
40°C to a max. of 50°C.
Room temperature adjustment (with optional room thermostat)
Using the room thermostat, set the temperature required in the rooms. If the room ther-
mostat is not installed, the boiler will keep the system at the set system delivery setpoint
temperature.
Room temperature adjustment (with optional remote timer control)
Using the remote timer control, set the required temperature in the rooms. The boiler will
adjust the system water according to the required room temperature. For operation with
remote timer control, please refer to the relevant instruction manual.
ECO/COMFORT selection
The unit has a function that ensures a high domestic hot water delivery speed and max-
imum comfort for the user. When the device is activated (COMFORT mode), the water
contained in the boiler is kept hot, thereby ensuring immediate availability of hot water
on opening the tap, without waiting times.
The user can deactivate the device (ECO mode) by pressing the eco/comfort button
(detail 7 - fig. 1). In ECO mode the display activates the ECO symbol (detail 12 - fig. 1).
To activate the COMFORT mode, press the eco/comfort button (detail 7 - fig. 1) again.
fig. 2 - Turning the boiler off
fig. 3
fig. 4
fig. 5
EN
3

Hide quick links:

Advertisement

Table of Contents
loading