Current Transducer Removal And Replacement - Lincoln Electric POWER WAVE 355/405 SVM159-A Service Manual

Lincoln electric welder user manual
Table of Contents

Advertisement

F-73

CURRENT TRANSDUCER REMOVAL AND REPLACEMENT

Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or
machine operator and will invalidate your factory warranty. For your safety and to avoid
electrical shock, please observe all safety notes and precautions detailed throughout this
manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical
troubleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
DESCRIPTION
The following procedure will aid the technician in removing the current transducer for
maintenance or replacement.
MATERIALS NEEDED
5/16" Nut Driver
1/4" Nut Driver
1/2" Nut driver
3/8" Nut Driver
Channel Locks
Flathead Screwdriver
Phillips Head Screwdriver
Hammer
Crescent Wrench
Pliers
This procedure takes approximately 45 minutes to perform.
TROUBLESHOOTING & REPAIR
WARNING
POWER WAVE 355/405
F-73