A-6
OPTIONAL FEATURES
INSTALLATION
Dual Procedure Switch Options
K683-1 Dual Procedure Switch (One per gun) -
Requires K686-2 Adapter for LN-10. Kit includes gun
switch, and mountings for Lincoln Innershield and
Magnum guns, with 15 ft. (4.5 m) control cable and 3-
pin plug. K686-2 Adapter permits 3-pin plug and 5-pin
gun trigger plug to be connected to LN-10 5-pin
Trigger/Dual Procedure receptacle.
Connect the 5-pin plug of the K686-2 Adapter to the
LN-10 Wire Feeder Trigger/Dual Procedure 5-socket
receptacle.
The 3-pin plug of the K683-1 Dual Procedure switch
connects to the 3-socket receptacle of the Adapter,
and the 5-pin plug of the welding un connects to the 5-
socket receptacle of the Adapter.
K683-3 Dual Procedure Switch Kit includes gun
switch, and mountings for Lincoln Innershield and
Magnum guns, with 15 ft. (4.5m) control cable and 5-
pin plug with two leads to connect to gun trigger.
Connect the 5-pin plug of the K683-3 Dual procedure
Switch to the LN-10 Wire Feeder Trigger/Dual
Procedure 5-socket receptacle.
The two lead plug cord extending out of the 5-pin plug
of the Dual Procedure switch is to be connected to the
two trigger leads of the welding gun per the instruc-
tions shipped with the kit.
K1449-1 Dual Procedure Remote Control
Provides remote rotating knob encoder control of Wire
Feed Speed and Voltage, along with a dual procedure
selector switch, when the remote control is connected
and REMOTE is selected by the LN-10 Procedure
key. The LN-10 A or B procedure light will also be on
to indicate which procedure is selected by the remote
control.
The 4-pin plug of the remote control connects to the
mating receptacle on the bottom of the LN-10 Control
box.
The K1450-"L" Extension cable is used to extend the
16 ft (5m) cable attached to the remote control.
Lengths "L" are available to match the Length of the
control to boom mount wire drive cable being used.
K1561-1 Robotics Interface Module - The module
plugs directly into the LN-10 control board and pro-
vides an interface to a properly equipped Fanuc robot.
INSTALLATION
When installed and properly configured, the K1561-1
Robotics Interface Module allows complete control of
the welding process from the robot controller.
The Lincoln Electric Companyʼs Automation Center
should be contacted for questions regarding installa-
tion or operation of the Robotics Interface Module.
All other options, see ACCESSORIES section, are
shipped with installation instructions.
LN-10
A-6