Red-D-Arc IM803-B Operator's Manual page 24

Lincoln electric welder user manual
Table of Contents

Advertisement

E-7
PROBLEMS
(SYMPTOMS)
Poor welding, weld settings drift, or
output power is low.
Poor stick electrode welding
performance. The arc pops out.
The thermal light and fan keep turn-
ing on and off.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con-
tact your local authorized field service facility for technical troubleshooting assistance before you proceed.
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
POSSIBLE
WELDING PROBLEMS
1. Make sure the machine settings
are correct for the weld process
being used.
2. Check machine performance on
LOCAL control. If OK then the
remote control device may be
faulty. Check or replace.
3. Check the input voltages and
input voltage reconnect
procedures. See Installation
Section of this manual.
4. Check for loose or faulty welding
cables.
1. Check for loose or faulty welding
cables.
2. Is the electrode DRY? Try weld-
ing with another electrode from a
different container. Make sure
you have the correct electrode for
the application.
3. Make sure the machine settings
are correct for the weld process
being used.
1. Check the input voltage section.
2. Check for blockage of vents,
which restricts air flow into or out
of the machine.
CAUSE
If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Authorized Field Service
Facility.
CAUTION
ES 275i
RECOMMENDED
COURSE OF ACTION
E-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Es 275i10994111661122311266

Table of Contents