A-10

GMAW SHIELDING GAS

WARNING
CYLINDER may explode if damaged.
• Keep cylinder upright and chained to
support.
• Keep cylinder away from areas where
it may be damaged.
• Never lift welder with cylinder attached.
• Never allow welding electrode to touch cylinder.
• Keep cylinder away from welding or other live elec-
trical circuits.
BUILDUP OF SHIELDING GAS may
harm health or kill.
• Shut off shielding gas supply when not
in use.
SEE AMERICAN NATIONAL STANDARD Z-49.1,
"SAFETY IN WELDING AND CUTTING" PUBLISHED
BY THE AMERICAN WELDING SOCIETY.
------------------------------------------------------------------------
Customer must provide a cylinder of shielding gas, a
pressure regulator, a flow control valve, and a hose
from the flow valve to the gas inlet fitting of the wire
drive unit.
Any shielding gas can be used that is recommended
in the electrode's product literature at a maximum
pressure of 60 psi (4.1 bar) This may include such
gasses as Argon, Helium, Nitrogen, and blended
gasses such Ar-He, Ar-N2, Ar-O2, Ar-CO2, CO2, and
Ar-CO2-O2.
Connect a supply hose from the gas cylinder flow
valve outlet to the 5/8-18 female inert gas fitting on the
back panel of the Wire Feeder. See ACCESSORIES
section for information regarding the optional Gas
Guard Regulator
Note: Included with the K1636-1 Power Feed 11
(Euro) ONLY is a barbed fitting and union nut
that can be installed on the 5/8-18 female inert
gas fitting on the back panel of the Wire Feeder
and allows for the connection of a 3/16"(5mm)
I.D. gas hose (Customer to provide appropriate
clamps).
INSTALLATION

LIFTING HANDLE

The Power Feed 11 is shipped with a insulated Lifting
Handle which can be mounted on the top or back of
the Wire Feeder. This handle is intended to be primar-
ily used for short term carrying of the Feeder. While
this handle is suitable for hanging the Feeder it is rec-
ommended that the Lifting Eyes also always be used
when hanging the Feeder. The procedure to mount
the Lifting Handle is as follows:
1) Turn Off the Welding Power Source
2) Open the Wire Drive Compartment Door and
remove the wire reel if present.
3) Using the appropriate socket and wrench(1/2")
remove the 2 screws and nuts from either the mid-
dle top or middle rear of the Feeder. The screws
are black in color and about 6.5" apart.
4) Using the hardware provided with the handle
secure the handle in the desired position.
Note: If it is desired to have handles in both the top
and back locations, an additional handle can be
ordered. ( Part Number S24131)