Lincoln Electric IM573 Calibration Information Manual page 21

Power wave pc board replacement calibration procedures
Table of Contents

Advertisement

21
SEMIAUTOMATIC PW450 FULL VOLTAGE CALIBRATION USING A WELDING ARC (continued)
NOTE: Do not attempt to weld for –Polarity
(+21A). Set the number to the same as
recorded for +Polarity (+67A). Also for
+Polarity and –Polarity, move the volt-
meter sense lead from the conductor
block of the wire feeder to the positive
output terminal on the front of the
machine.
9. Turn the machine off.
Synergic 7 to the Wire feeder 2 amphenol
on the back of the Power Wave machine.
10. Put the voltmeter sense lead back on the
wire feeder conductor block and repeat
the calibration process steps 5, 6, and 7
for the following test points:
NOTE: Do not attempt to weld for –Polarity
(+21B). Set the number to the same as
recorded for +Polarity (+67B).
CALIBRATION
– POLARITY (+21A)
+ POLARITY
– POLARITY
Connect the
+POLARITY (+67B)
–POLARITY (+21B)
POWER WAVE CALIBRATION
21