Wire Feeder Control Cable Connections
Lincoln wire feeders can be hooked up to either the
14-pin Wire Feeder Receptacle (#12, Figure 3), or to
the terminal strip (behind #11, Figure 3). The Wire
Feeder Receptacle is the preferred method, because
it virtually eliminates accidental miswirings.
For connection to the Wire Feeder Receptacle, choose a control cable from the chart below:
Wire Feed Unit
LN-7
LN-8 / LN-9
NA-5
* Cables are available in various lengths. Consult your welding equipment distributor for availability.
For connection to the terminal strip, consult your
Lincoln distributor for the appropriate wire feeder
control cable. Feed the control cable end through the
box connector on the case front, to provide a strain
relief for the cable. Connect the numbered leads in
the control cable to the terminals on the terminal strip,
as depicted in Figure 4. For example, for cables with
DC-650 PRO
Figure 3
Current Capacity
400A
600A
1000A
–
12
Duty Cycle
60%
60%
80%
leads A, B, and C, connect A to 75, B to 76 and C to
77, connect lead 2 to terminal 2, lead 4 to terminal 4,
etc. Connect the green ground lead to the stud
marked
.
–
Cable Type *
K480-XX
K595-XX
K597-XX