8-5-3. Evacuating
After the piping has been connected to the indoor unit,
you can perform the air purge together at once.
AIR PURGE
Evacuate the air in the connecting pipes and in the
indoor unit using
a vacuum pump. Do not use the refrigerant in the
outdoor unit.
For details, see the manual of the vacuum pump.
<Using a vacuum pump>
Be sure to use a vacuum pump with counter-flow
prevention function so that inside oil of the pump does
not flow backward into pipes of the air conditioner
when the pump stops.
1. Connect the charge hose from the manifold valve to
the service port of the gas side packed valve.
2. Connect the charge hose to the port of the vacuum
pump.
3. Open fully the low pressure side handle of the
gauge manifold valve.
4. Operate the vacuum pump to start evacuating.
Perform evacuating for about 15 minutes if the piping
length is 20 meters. (15 minutes for 20 meters)
(assuming a pump capacity of 27 liters per minute.)
Then confirm that the compound pressure gauge
-
-
reading is 101 kPa ( 76 cmHg).
5. Close the low pressure side valve handle of gauge
manifold.
6. Open fully the valve stem of the packed valves
(both sides of Gas and Liquid).
7. Remove the charging hose from the service port.
8. Securely tighten the caps on the packed valves.
Compound pressure gauge
-
101 kPa ( 76 cmHg)
-
Handle Lo
Charge hose
Connecting pipe
Packed valve at gas side
Service port
(Valve core (Setting pin))
Packed valve at liquid side
Fig. 8-5-7
<Packed valve handling precautions>
·
·
Pressure gauge
Manifold valve
Handle Hi
(Keep full closed)
Charge hose
Vacuum pump
adapter for
counter-flow
prevention
Vacuum
pump
- 54 -
FILE NO. SVM-05001
Open the valve stem all the way out; but do not try
to open it beyond the stopper.
Securely tighten the valve stem cap with torque in
the following table:
Gas side
Æ
( 12.70 mm)
Gas side
Æ
( 9.52 mm)
Liquid side
Æ
( 6.35 mm)
Service port
Fig. 8-5-8
50 to 62 Nám
(5.0 to 6.2 kgfám)
30 to 42 Nám
(3.0 to 4.2 kgfám)
16 to 18 Nám
(1.6 to 1.8 kgfám)
9 to 10 Nám
(0.9 to 1.0 kgfám)
Hexagonal wrench
is required.