Specification Of Electrical Parts; Indoor Unit (Ras-18Skpx, Ras-18Skpx-V, Ras-18Skp-E); Outdoor Unit (Ras-18S2Ax, Ras-18S2Ax-V, Ras-18S2A-E) - Toshiba RAS-18SKPX Service Manual

Split wall type
Table of Contents

Advertisement

4. SPECIFICATION OF ELECTRICAL PARTS

4-1. Indoor Unit (RAS-18SKPX, RAS-18SKPX-V, RAS-18SKP-E)

No.
Parts name
1
Fan motor (for indoor)
2
Thermo sensor (TA-sensor)
3
Switching Transformer (T01)
4
Microcontroller
5
Heat exchanger sensor
(TC-sensor)
6
Line filter (L01)
7
Diode (DB01)
8
Capacitor (C27)
9
Fuse (F01)
10
Varistor (R62, R63)
11
Resistor (R64)
12
Louver motor

4-2. Outdoor Unit (RAS-18S2AX, RAS-18S2AX-V, RAS-18S2A-E)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Magnetic contactor
Type
AFS-220-31-4A
———
ST-001
TMP87CM40ANG-6P68
———
LC*SS11V-06270
DB105G
EKMH401VSN470MP20S
FJL250V6.3A
SR561K14DL
RF-2TK5R6
MP24Z3T
Type
Output (Rated) 1500 W, 2 poles, 1 phase, 220-240V~, 50 Hz
SHX33SC4-U
Winding resistance (Ω)
(at 20°C)
Output (Rated) 42 W, 6 poles, 1 phase, 220 – 240 V~, 50 Hz
WLF-240-42A-1
Winding resistance (Ω)
(at 20°C)
AC450V~, 2.0µF
DS451205NPQB
RS44B506U0218S AC440V~, 50µF
CLK-26J
220-240V~, 50 Hz
– 11 –
FILE NO. SVM-08032
Specifications
AC 200 − 240V, 31W
10 kΩ at 25°C
10 kΩ at 25°C
27mH, 600mA
1 A, 600 V
47 µF, 400 V
T6.3 A, 250 V
560 V
5.6Ω , 2W
Output (Rated) 2 W, 6 poles, 1-2 phase,
DC 12 V
Specifications
C-R
1.47
Red-Black
188
C-S
2.88
White-Black
289