Engineer Code - Menvier Security TS510 Installation & User Manual

Hide thumbs Also See for TS510:
Table of Contents

Advertisement

TS510 & TS500
OUTPUT 1:
Press [6] [5] and one of the following
LEDs will light, showing which function
is indicated by Output 1:
LED
1
ON
SW12V
WALK
FOR:
TEST
ON/OFF ON/OFF ON/OFF ON/OFF
OUTPUT 2:
Press [6] [6] and one of the following
LEDs will light, showing which function
is indicated by Output 2:
LED
1
ON
FAULT
SW 12V
FOR:
ON/OFF ON/OFF ON/OFF ON/OFF
KEYSWITCH FINAL EXIT:
Press [6] [7] and one of the following LEDS
will light, showing how the keyswitch input will
operate.
LED
1
2
FULL SET
PART SET
ON
A
FOR:
ON/OFF
ON/OFF
VIEW EVENT LOG:
Pressing [6] [8] will allow the event log to be
viewed. Pressing [8] displays the last event
whilst pressing numbers other than [9] and
[0] displays earlier events in order, with [1]
being the oldest event. To exit the routine,
press [0].
SYSTEM SETTING OPTIONS:
Press (6) [9] to select the system setting
options.
LED
1
ON
SET ALLOWED
RISING ENTRY
WITH MAINS
AND EXIT
FOR:
FAILURE
OFF
SET
CONTINUOUS
FOR:
DISALLOWED
ENTRY AND
WITH MAINS
EXIT TONES
FAILURE
TS510 & TS500
2
3
4
DTR
ALARM
RESET
2
3
4
DTR
PA
RESET
3
4
PART SET
FINAL
B
EXIT
ON/OFF
ON/OFF NOT USED
2
3
SET ALLOWS
WITH LINE
TONES
FAULT
SET
DISALLOWED
WITH LINE
FAULT

ENGINEER CODE:

Press [7] and 4 zone LEDs will light indicating
that a 4 digit engineer code is required.
Once entered, re-enter the code for
confirmation and listen for the confirmation
tone.
5
NOT
ENGR CODE
USED
NOT
USED
REMOTE RESET CODE:
Press [8] and 3 zone LEDs will light, indicating
that a 3 digit code must be entered. Enter
your code and listen for the confirmation
tone.
5
NOT
OPTIONS:
USED
NOT
Press [9] and a combination of zone LEDs will
USED
light, each showing a different setup. To
change any option, simply enter the number
for the options required. Once the settings
are correct, press [0] and listen for the
confirmation tone.
LED
5
ON
ET/F EXIT
NOT USED
FOR:
OFF
FOR:
CHIMES
NOTE: Whilst in engineer mode, tampers are
inhibited. To monitor tampers return the panel to the
UNSET condition.
NOTE: OPTIONS: No.5 on TS500 LED ON = AUTO
RE-ARM, LED OFF = MANUAL RE-ARM
4
5
NOT
NOT
USED
USED
NOT
NOT
USED
USED
8 of 10
RESET NO.
1
2
3
FINAL
E.T.
SILENT
EXIT
ENABLED
SET
ET/F
TIMED
E.T.
EXIT
EXIT
DISABLED
DEFAULT = 1234
DEFAULT = 004
4
5
ENGINEER
3
RESET
REARMS
0
USER
RESET
REARMS
496525 Issue A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ts500

Table of Contents