Model 64100A - General
Info~ation
1-9. The-four areas of the Rear panel are Power Control, HP-IB system interface
bus,
RS-232 serial interface,
and system control source.
The power functions
are on the lower right-hand side of the rear panel.
The model 64100A requires
110/220 VAC
+/-15%,
48-66
HZ.
The position of the LINE SELECTOR determines
either 110 V (10 AT fuse)
or 220 V
(5 AT fuse)
operation.
The power ON/OFF
switch is a rocker type.
1-10. A card cable opening is provided to the outside of
the mainframe through
the space between the rear of the top
cover and rear
panel. Three slots
with
clamps are provided for access.
Cable length for option boards
is determined
at the factory and are shipped at maximum length.
1-11. There are 13 PC board slots (see figure 1-3).
The first three slots have
printed circuit boards installed
at
the
factory.
These PC
boards
must
be
installed
in
the order
given
for
the
64000 system to operate.
The three
required boards are:
slot A - I/O PC Board
slot B - Display Control PC Board
slot C - CPU PC Board
1-12. For convenience,
board identifier labels for the
first three boards are
located just
above
the cardcage on
the left-hand
side.
The remaining
ten
option slots are numbered 0-9.
1-13. The PC boards
interface
to the system through
the
motherboard on
the
bottom of the
card
cage.
A cable from the Rear Panel PC board
(on the rear
panel) makes connection to the top center connector on the I/O board.
1-14. There is
a
limit to
the
number and types of option boards that may
be
installed in
the
cardcage without exceeding the
capability
of the
400 watt
Power Supply.
This limit is determined by the amount of available current from
the power
supplies.
Table
1-1 lists the power
supply current drain for the
mainframe with only the three mandatory boards installed.
MF 1-2
Table 1-1.
Basic Power Supply Current Drain
ITEM
Processor ,ROM
I/O
Disp Control,RAM
Keyboard
Display Driver
Rear Panel
Bus Pullups
Subtotal
Available Current
(NO OPTIONS INSTALLED)
+12V
0·595
0.164
0.640
1·500
2.899
4 Amps
+5V
1.429
0.708
1·533
0.100
0.714
0.070
4.793
45 Amps
-5V
0.0003
0.0064
0.239
0.2457
25 Amps
-12V
0.078
0.078
1 Amp
-3V
0.0003
0.0064
0.239
0.2457
30 Amps

Advertisement