6. Convenient GUI / Touch Screen
Not requires special education for using the Deluxe Central control, conveniently used only by pressing the
buttons on the screen, and its function can be understood with intuitive pictogram. Especially schedule setting
is done by simply dragging the screen as patented technology differently from the existing system requiring to
press the button by more than average 30 times to enter a schedule.
7. Schedule Automatic Operation Management / Energy Saving
For the Schedule Automatic Operation, weekly setting is available. Enlisting of the schedule exception pro-
cessing schedule (national holiday) is done for a year prevents the air conditioner from an unnecessary oper-
ation of air conditioner, allowing the system to be controlled at the center so that it can be only used for a nec-
essary case and enabling to obtain excellent energy savin effect. Use of this function if there is a fixed sched-
ule for elementary schoo, middle school, high school and college or university will get excellent effect.
8. Power Failure Backup Function / Powerful Stability
For the existing Central Control System, additional purchase of expensive UPS equipment in provision for a
temporary power failure must be done in the past but for the Deluxe Central control, since the self-power fail-
ure compensation battery is built-in, power is automatically converted by maximum 2 hours. Therefore, there
is almost no malfunction due to a temporary power failure because stable operation is available.
9. Mobility
A wireless radio system may be installed at the Deluxe Central control. You may control the system while
directly going around the building with the wireless radio system and its self-battery function (100 m where
there is no obstacle).
10. Convenient Installation
This system may be freely fixed to the wall surface with its small size, light weight and thin thickness and
stood up on the desk by using a dedicated cradle. It is not almost subject to spatial restriction in installation
space and location since this system communicates with on the basis of the I-GW and the Ethernet.
11. Stable Date Storage/Backup
Setup information is saved as it is even if no power is supplied since all date are saved in the built-in flash
memory.
12. Scalability
Scalability of the system is easy in case of additionally purchasing equipment since scalable slot such as
USB, Serial (RS-232c), PCMCIA, CF Type is prepared. This system is designed considering sufficient scala-
bility in provision for special request by the customer.
13. Upgrade
Additional installation of a new program is available via the CF memory card and the existing program can be
upgraded to a new program. Using such upgrade function always enables to construct a modern type of
Central Control System.