ADJUSTMENTS
SETTING THE TIMER
Single Operator
To use the automatic close for the gate system the
timer switch should be put in the "ON" position.
To use the push close command,
the timer should be
switched to the
"OFF" position.
Push button
once to open
gate, push
button again to
close gate.
Primary/Secondary Operators
Operators need to be connected by M/S LINK. See Linking Primary/Secondary page 19.
M/S LINK
Primary Board
Primary Board
Primary/Secondary control boards are interchangeable.
With Timers ON
1. Turn Primary timer ON.
2. Turn Secondary timer OFF.
3. Use Timer on Primary Board Only.
(3 to 60 seconds)
NOTE: If a secondary photoelectric sensor
device is NOT used when the timer is ON, the
gate WILL hit a vehicle obstructing the gate
path before reversing during the close cycle.
With Timers OFF
1. Turn BOTH timers OFF.
NOTE: Push button once to open gate,
push button again to close gate.
30
Set timer 3 to 60
seconds.
Secondary Board
Secondary Board