Fireplace Maintenance; Glass Door Maintenance - Majestic B36LA Installation, Operation And Maintenance Instructions

Wood burning fireplace
Table of Contents

Advertisement

B36LA & B36RA Woodburning Fireplaces

Fireplace Maintenance

At the end of each heating season or when the fireplace will not be in use for an extended time, the
ashes should be removed and the hearth area should be swept as clean as is practical. The slow ab-
sorption of moisture into the ashes over a long period of time could cause a condition which would be
corrosive to the metal fireplace parts.
At the beginning of each heating season, always operate the flue damper and make sure it has not
become stuck from soot, creosote, etc., during the period of inactivity.
Keep the lower and upper grille panels clean and free from dirt and lint accumulation at all times to get
the maximum efficiency from your fireplace.
As you use the fireplace, expansion and contraction will cause minor cracking of the hearth, back, and
side refractory materials. This is normal and unavoidable. If the cracks become large enough or parts
dislodge and metal behind the refractory is exposed, the refractory panels should be replaced with new
panels that can be obtained from you fireplace dealer.

Glass Door Maintenance

For glass door maintenance, see instructions provided with the glass doors.
Checklist of Do's and Dont's
DO'S
1. Do check with local building officials to be sure the installation of the fireplace complies with all
building codes and requirements and obtain required building permits. Do plan your installation with
safety as you primary consideration.
2. Do use only the prescribed material and parts for the installation of the fireplace.
3. Do insulate the exterior walls surrounding the fireplace to prevent excessive heat loss from the
fireplace.
4. Do trim the face of the fireplace only with noncombustible materials.
5. Do attach the noncombustible face trim material firmly to the face of the fireplace.
6. Do block in or fasten the fireplace to prevent the possibility of the fireplace shifting out of position.
7. Do connect the air circulation blower to a properly grunded and fused electrical circuit.
8. Do enclose the chimney where it passes through living spaces or spaces accessible for storage
purposes to prevent contact with and possible damage to the chimney.
9. Do install firestop spacers at each ceiling level when the chimney is installed in a multistory build-
ing.
10. Do install the proper chimney cap or chimney housing on the chimney to prevent rain and debris
from entering the chimney.
11. Do keep all flammable liquids, gases and pressurized containers away form the fireplace.
12. Do check the fireplace for proper adjustment and operation before leaving it unattended for long
periods of time.
13. Do inspect and clean the fireplace chimney regularly.
14. Do keep the fire screens closed when the fireplace is left unattended to minimize the danger of
sparks popping out of the fireplace.
15. Do use the grate furnished with and for this fireplace.
16. Do start a fire only with paper, kindling or solid composition fire starters specifically designed for
starting a fire. The use of liquid fire starter can cause an explosion within the fireplace.
17. Do place all ashes in a metal container with a tight fitting lid and place them on a noncombustible
surface well away from other combustible materials until they have completely cooled.
18. Do store your fuel supply at a distance equal to or greater than the spacing recommended for com-
bustible materials from the fireplace.
19. Do build fires of moderate intensity in the fireplace for the first three fires to allow materials to adjust
and cure before being subjected to the intense heat of a large fire.
30