SITE REQUIREMENTS - Page 6
FIG. 4 FLUE LENGTHS
ELECTRICITY SUPPLY
A 240 volts ~ 50Hz, single phase electricity supply fused to
3 amperes, must be provided in accordance with the latest
edition of the I.E.E. Wiring Regulations and any other local
regulations that may apply. The current rating of the wiring
to the boiler must exceed 3 amperes and have a cross
sectional area of at least 0.75mm
BS6500 1975 Table 16.
TECHNICAL DATA - Page 6
Maximum working head
Minimum working head on
Fully Pumped systems
Minimum circulating head
on Gravity systems
Gas supply pressure
Maximum Flow temperature
Electricity supply
Flow/Return connection
Power consumption
ALL MODELS REAR OR SIDE FLUEING
2
in accordance with
30.5m (100 ft)
305mm (1 ft)
1.2m (4 ft)
37mbar
0
82
C
240v ~ 5OHz fused
at 3A
28mm copper
80 watts
(excluding pump)
The supply to the boiler and its associated equipment
should be controlled by an exclusive 3A fused double pole
switch (having at least 3mm contact separation in both
poles) so that complete isolation from the supply can be
achieved to enable servicing work to be carried out in
safety.
Gas supply connection
Water Content
Appliance Weight-installed
Appliance Weight-lift
Rc. ½ (½in BSP
Female)
6.5 litre (1.43 gal)
62kg (137 Ibs)
53kg (117 Ibs)