IMPORTANT This appliance must be installed and serviced by a competent person as stated in the Gas Safety (Installation
and Use) Regulations 1994.
Profile LPG boilers have been designed to comply with the requirements of BS 5258 Part 1 and BS 6332 Part 1. It is
important that no external control devices (e.g. flue dampers, economisers, etc.) be directly connected to these appliances
unless covered by these installation instructions or otherwise recommended in writing. Any direct connection of a control
device not approved by Potterton could invalidate the normal warranty.
GENERAL - Page 2
Potterton Profile LPG boilers are fully automatically
controlled wall mounted fan powered balanced flue
appliances, using a cast iron heat exchanger and are
available in three outputs. 14.7 kW (50000 Btu/h), 17.6 kW
(60000 Btu/h) and 23.44 kW (80000 Btu/h).
The boilers which are designed to provide domestic hot
water and/or central heating must be used on INDIRECT
hot water systems only. The cast iron heat exchangers are
suitable for use on open vented gravity domestic hot
OPTIONAL EXTRAS - Page 2
The following are kits available as optional extras:-
Internal Fitment Kit, which is suitable for a maximum wall
thickness of 510mm (20 in.) is to be used where access to
the outside wall is impracticable.
Pump Cover KIts, located on top of the boiler and
designed to conceal the pump, and/or any motorised
valves installed above the boiler. (Note: Pump cannot
be fitted above the boiler if the vertical flue kit is used.
Terminal Wall Plate, where necessary can be fitted to
the outside wall face to improve the appearance, after
making good around the terminal.
GAD (90/396/EEC)
Health and Safety Information
Control Systems, Pipework and
Wiring Guide
User's Instructions
All boilers can be supplied with either of the following types
of flue system:
1) Standard horizontal flue system suitable for wall
2) 2 metre horizontal flue system which provides a
3) Vertical flue system which allows the flue to pass
Terminal Guard, to be used when the terminal is fitted less
than 2m above a balcony, above ground or above a flat roof
to which people have access.
Full fitting instructions are provided with each kit.
PART Nos
Standard Flue system
2 metre Flue System
Vertical Flue system
Terminal Wall Plate
Terminal Guard
Internal Fitment Kit
Pump Cover Kit (6in)
Pump cover Kit (71n - 12in)
Pump Cover Kit (l3in - l8in)
Pump Cover Kit (l9in - 24in)
2
1
thickness of 100mm (4 in.) to 510mm (20 in.).
maximum flue length of 1955mm (77 in.).
through a flat roof and terminate at a maximum height
of 1980mm (78 in.) measured from the top of the boiler
case.
5Oe
225540
225543
213074
212306
205792
225183
225418
225419
225420
225421
Back Page
Supplied in
Literature Pack
60e
80e
225541
225541
225544
225544
213048
213049
212280
212280
205792
205792
225184
225184
225418
225418
225419
225419
225420
225420
225421
225421

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lpg 60eLpg 80e

Table of Contents