2) MANDATORY MODIFICATIONS
A) On KLM-366:
Enable voice gates in tape interface mode:
• Cut pcb trace IC4/pin1 to via (component side).
• Connect IC4/pin1 to IC4/pin16.
Separate UNISON LED from unison detune function:
• Remove R118 (10k).
• Connect IC5/pin13 to IC2/pin14.
• Connect IC2/pin15 to IC30/pin6.
Separate CHORD MEMORY pushbutton from footswitch input:
• Cut pcb trace to D3/anode (component side).
• Connect D3/anode to IC6/pin33.
B) On KLM-367:
Remove the backup battery. There is a lithium battery on the new MIDI pcb you received.
Disable mute circuit during tape interface mode:
• Cut pcb trace to IC5/pin3 directly at IC5/pin3 (solder side). Be sure not to damage the passing by pcb trace.
• Connect IC5/pin3 to IC5/pin7.
Connection cable to MIDI pcb:
• Solder the open ends of the supplied 10 way cable (drawing no. PS 6M 00 05 004) to the respective target
points on KLM-367 (refer to picture and drawing).