17) Individual Parameter Update
Newly recognized MIDI commands allow for individual parameter update in realtime:
MIDI Controller CC06
MIDI Controller CC96
MIDI Controller CC97
MIDI Controller CC98
MIDI Controller CC99
A) Use of NRPN
Paramter selecting is done by MIDI controller CC98/99 (NPRN). There is a conversion table used for parameter
seletcion:
62h (CC98)
63h (CC99)
0
0..5
1
6..11
2
12..17
3
18..23
4
24..29
5
30..35
6
36..41
7
42..47
8
48..53
9
54..59
10
60..65
11
66..71
12
72..77
13
78..83
14
84..89
15
90..95
16
96..101
17
102..107
18
108..113
19
114..119
20
120..125
21..127
126..127
B) Editing a parameter
(1) Send NRPN (CC98, CC99) message to select corresponding parameter.
(2) Send either Data Entry (CC06) message with new value of parameter. The received Data Entry value (range
0..127) is multiplied by two to achieve the whole byte range (0..254) .
OR (alternatively or additionally) send Data In/Decrement message to do UP/DOWN editing.
Note: - Only the highest bits of a Data Entry message will be significant for a switch parameter.
- No fiddling with bits or similar is necessary.
12
(DATA entry)
(DATA increment)
(DATA decrement)
(Non Registered Parameter Number, fine)
(Non Registered Parameter Number, coarse)
PolySix parameter name
OCTAVE
WAVEFORM
PW/PWM
PWM SPEED
SUB OSC
FILTER CUTOFF
FILTER RESONANCE
EG INTENSITY
KBD TRACKING
VCA EG MODE
ATTENUATOR
BEND MODE
MG SPEED
MG DELAY
MG LEVEL
MG MODE
ATTACK
DECAY
SUSTAIN
RELEASE
EFFECT MODE
EFFECT SPEED