3-3. Charge Function Check
Note1: When perform this check, don't apply a voltage to battery terminals.
Note2: Be sure to disconnect the AC adapter when connecting the resistors.
Doing so with the power supply connected causes a trouble.
3-3-1. Voltage adjustment and checks
Procedure:
1. Connect the digital multi meter to battery terminals.
2. Connect the AC adapter to the set.
3. Enter the test mode (Display Check mode).
4. Press the [VOL+] key to enter the Manual mode.
5. Press the [VOL+] key twice, press the
[VOL+] key once, press the
key three times to display as follows.
Display of the remote commander
260 ChrgNi
6. Press the
key to select the item number 2261 and display
>
as follows.
Display of the remote commander
261 ChgAdj
adjustment value (hexadecimal)
7. Adjust with [VOL+]/[VOL--] keys so that the value of digital
multi meter becomes 1.80 ± 0.01V.
8. Press the
key on the set or
X
commander to write the adjusted value.
9. Press the
key to select the item number 2262.
>
10. Confirm that the value of digital multi meter is 1.20 ± 0.024V.
11. Press the
key to select the item number 2263.
>
12. Confirm that the value of digital multi meter is 2.17 ± 0.05V.
13. Press the
key four times and back to the Display Check
x
mode.
3-3-2. Ampere checks
Procedure:
1. Connect the 22 ohms resistor (more than 0.1 watts) and ampere
meter to battery terminals.
2. Connect the AC adapter to the set.
3. Enter the test mode (Display Check mode).
4. Press the [VOL+] key to enter the Manual mode.
5. Press the [VOL+] key twice, press the
[VOL+] key once, press the
key three times, press the
item number 2264.
6. Confirm that the value of ampere meter becomes specification
value. (Refer to "table 3-3-1. Ampere Specifications")
7. Press the
key four times and back to the Display Check
x
mode.
8. Cut the power supply and remove the resistor that connected
to the battery terminals.
9. Repeat checks to item number 2267 at the same manner as
step 1 to step 8. ( Refer to "table 3-3-1. Ampere Specifications"
for the kind of the resistor that connected to the battery
terminals at step 1)
ItemNo.
Display
Specification value
20 mA ± 11 mA
2264
20mA I **
140 mA ± 14 mA
2265
140mAI **
170 mA ± 15 mA
2266
170mAI **
500 mA ± 32 mA
2267
500mAI **
Table 3-3-1. Ampere Specifications
18
key once, press the
>
key once, press the [VOL+]
>
**
key on the remote
key once, press the
>
key once, press the [VOL+]
>
key four times to select the
>
Connected Resistor
22Ω (more than 0.1W)
10Ω (more than 1.0W)
10Ω (more than 1.0W)
2.2Ω (more than 1.5W)
3-4. Laser Power Check
Procedure:
1. Enter the test mode (Display Check mode).
2. Press the [VOL+] key to enter the Manual mode.
3. Open the lid and press the
optical pick-up moves to the most inward track.
4. Press the [VOL--] key once to display as follows.
Display of the remote commander
009 DESIGN
5. Press the
key three times to select the item number 9111
>
and display as follows.
Display of the remote commander
111 LrefPw **
6. Set the laser power meter so that the laser beam from the optical
pick-up aims at the objective lens of laser power meter at right
angle. (Confirm it with the disc not inserted)
7. Confirm that the value of laser power meter is 0.860 mW ±
19.2%.
8. Press the
key to select the item number 9112.
>
9. Confirm that the value of laser power meter is 0.763 mW ±
18.2%.
10. Press the
key to select the item number 9113.
>
11. Confirm that the value of laser power meter is 6.87 mW ±
12%.
12. Press the
key four times and back to the Display Check
x
mode.
3-5. Setting The Adjustment Values
3-5-1. Hi-MD3 setting
Preparation:
1. Perform calculation every item based on the data given by the
Hi-MD3 adjustment disc by referring to the following table.
(Round off the value in decimal place)
2. Convert the calculated value into hexadecimal number.
Note: The Hi-MD3 adjustment parameters vary depending on the disc,
and therefore use the parameters of the disc used when performing
the adjustment.
Item No.
Calculating formula (*3)
0211
Pr_nominal / 0.05
(*1)
Por / 0.05
Kr × (−100)
0212
0213
Pw_nominal / 0.05
(*2)
Ppw / 0.05
Kw × (−100)
0214
0215
Prmin / 0.05
0216
Pwmin / 0.05
*1) If the "Pr_nominal" value is indicated, use the "Pr_nominal" value
and not used "Por" value.
*2) If the "Pw_nominal" value is indicated, use the "Pw_nominal" value
and not used "Ppw" value.
*3) Round off after the decimal point.
Table 3-5-1. Hi-MD3 adjustment parameter