Peavey IPR2 5000 Operating Manual page 34

Power amplifi ers
Hide thumbs Also See for IPR2 5000:
Table of Contents

Advertisement

Rated Watts 2ch x 2 ohms
Rated Watts 2ch x 4 ohms
Rated Watts 2ch x 8 ohms
Minimum Impedance
Maximum RMS Voltage Swing
Frequency Response
20Hz - 20kHz 2ch x 2 ohms
20Hz - 20kHz 2ch x 4 ohms
20Hz - 20kHz 2ch x 8 ohms
Input CMRR
Voltage Gain
Crossover
Crosstalk
Hum and Noise
Slew Rate
Damping Factor (8 ohms)
Input Sensitivity
Input Impedance
Current Draw @ 1/8 in VA (watts)
Current Draw @ 1/3 in VA (watts)
Idle Consumption
Cooling
Controls
Indicator LEDs
Protection
Connectors
Construction
Dimensions
Net Weight
Gross Weight
Rated power readings made with BW: 20 Hz to 22 kHz. All power measurements made @ 120 VAC or 240VAC.
2 ohm steady state sine wave power is time limited by circuit breaker.
Bridge operation is not possible.
*Net Weight does not include power cord.
IPR2
7500 Specification Sheet
4750 watts 20ms repetitive burst / 3750 watts 1% THD both channels driven @ 1kHz.
2800 watts 20ms repetitive burst / 2450 watts 1% THD / 2020 watts 0.15% THD, both channels driven @ 1kHz.
1550 watts 20ms repetitive burst / 1425 watts 1% THD / 1200 watts 0.15% THD, both channels driven @ 1kHz.
2 ohms
124 volts
20Hz - 25kHz; +0dB, -3dB
<0.5% @ 3280 watts 20Hz to 4kHz, decreasing to 3000 watts @ 20kHz, both channels driven.
<0.15% @ 2000 watts 20Hz to 20kHz, both channels driven.
<0.15% @ 1200 watts 20Hz to 20kHz, both channels driven.
> - 75dB @ 1 kHz.
x 40 (+32dB)
100Hz switchable 2nd order high pass and 3rd low pass per channel.
> -85dB @ 1kHz @ 1000 watts power @ 8 ohms.
> -106dB, "A" weighted referenced to rated power @ 4 ohms.
> 12V/μs
> 200:1 @ 20Hz - 1kHz @ 8 ohms
2.25 volts +/- 3% for 1kHz 4 ohm rated power, 2.195 volts +/- 3% for 1kHz 2 ohm rated power
20 kilohms, balanced and 10 kilohms unbalanced.
2210 (1440) @ 2 ohms, 1550 (950) @ 4 ohms, 982 (560) @ 8 ohms
4260 (3150) @ 2 ohm, 3120 (2160) @ 4 ohms, 1890 (1200) @ 8 ohms
250VA, 120 watts.
3 temperature dependent variable speed fans.
2 front panel attenuators, crossover select switch for HPF, Normal and LPF
Five LED indicators per channel: Active, Signal, DDT, Temperature and DC
Thermal, DC, subsonic, incorrect loads, under and over voltage
Inputs: Dual combination 1/4" XLR, Outputs: Dual 1/4" thru, one 2-pin & one 4 pin twist-lock connector
0.062" thick aluminum
3.5"x19"x 17" behind front panel + 0.6" for handle
6.61kg (14.6lbs.*)
8.34kg (18.4lbs.)
34

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ipr2 7500

Table of Contents