Advertisement

Available languages

Available languages

PREPARATION
Tools Required for Assembly (not included): Hammer, Flathead Screwdriver, Wire Nuts, Nails, Duct Tape,
Phillips Head Screwdriver, Utility Knife
Helpful Tools (not included): Electric Drill, Drill Bits
WARNING: Turn off electricity at breaker box before beginning installation.
Carefully remove unit from carton.
Check area above installation location to be sure that wiring can run to the planned location and that
duct work can be run and the area is sufficient for proper ventilation.
Inspect duct work and wiring before proceeding with installation.
Before installation, provide inspection and future maintenance access at a location that will not interfere
with installation work.
You may need the help of a second person to install this fan: one person on the attic side and one on
the room side.
Note: Installations may vary depending on how the previous bath fan was installed. Supplies necessary
for the installation of your bath fan are not all included; however, most are available at your local
home improvement or hardware store.
DIMENSION REQUIREMENTS
Ceiling
Opening (L)
Opening (W)
10.25 in.

WIRING DIAGRAM

QUICK CONNECTOR INSTRUCTIONS
To be sold only with installation instructions.
WARNING: Wiring must comply with all applicable electrical codes. Turn
OFF power before removing or installing connectors.
WARNING: COPPER TO COPPER ONLY. Do not use Aluminum wire.
CAUTION: Accessory part (quick connector) should meet installation
instructions.
NOTE: The connector is reusable on solid wires of the same wire gage or
smaller. Do not reuse the connector on stranded wires.
NOTE: Important wire information. Maximum temperature rating 105º C
(221º F). 600 volts maximum for building wire and 1000 volts maximum in
signs and lighting fixtures. The acceptable wire range includes:
Solid: 12-18 AWG.
Ceiling
Ceiling
Opening (H)
10.25 in.
8.25 in.
Housing
Dimension (L)
9.68 in.
House
wires
• Strip wires 3/8"-1/2"
• Grip the wire firmly and push the stripped end of the wire into
the open port of the connector. Use only one conductor per port.
• Verify the stripped end of the wires is fully inserted to the back of
the connector.
5
Housing
Housing
Dimension (W)
Dimension (H)
9.68 in.
7.98 in.
Quick
connector
Product
wires
Lowes.com

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents