Day Program Setting; 1 X Dhw - Wolf AWT Installation And Operation Instructions Manual

Weather-compensated analog control thermostat with day program for gas fired boilers
Table of Contents

Advertisement

Day program setting

Day programs for central heating and DHW
cylinder loading (for boilers with DHW
cylinders) or DHW QuickStart are set using the
DIP switches under the front flap.
Heating mode settings and enabling DHW
cylinder loading/DHW QuickStart: Push the DIP
switch
up for the required period.
The set room temperature for heating mode
will be used.
Economy mode or central heating OFF (subject
to the program selector setting): push the DIP
switches for the required period down
The selected set room temperature for economy
mode is used or the central heating is switched
OFF. DHW loading or DHW QuickStart are
disabled.
The shortest switching period is 30 minutes.
Note: The day program settings will only
be active, if the program selector has
been set in accordance with the day
program
,
q
q
C
B
B i

1 x DHW

If DHW is required outside the period where
DHW loading is enabled, the DHW cylinder can
be heated to the set temperature by means of
function "1 x DHW". Pressing keys
simultaneously either activates or deactivates
this function. In the activated state, a flashing
arrow appears on symbol
DHW" will be deactivated automatically after
one hour.
1 x DHW
/
i
C
or
.
q
and
. Function "1 x
Day program setting / 1 x DHW
Contractor level
Day program example
.
Heating ON from 06.00 - 22.00 h
Heating OFF/economy from 22.00 - 06.00 h
For boilers with DHW cylinder loading
enabled from 6.00 - 22.00 h
DHW cylinder loading disabled
from 22.00 - 06.00 h
x
1
q
C
Key combination for "1 x DHW"
C
i
Display during "1 x DHW"
DIP switch