120 Furnace Connection - Napoleon 9600 SERIES Installation And Operating Instructions Manual

Two stage natural and propane gas high efficiency (condensing) forced air furnace
Table of Contents

Advertisement

42
In Canada, all electrical work must be in accordance with the latest
edition of CSA-C22.1, Canadian Electrical Code Part 1, and any
applicable local code.
In the United States, all electrical work must be in accordance with
the latest edition of the National Electrical Code, ANSI / NFPA 70.
Although a suitably located circuit may serve as a service switch,
a separate service switch is recommended. A separate service
switch is necessary if the circuit breaker is in a location where
accessing it would require getting close to the furnace, or if the
furnace is located between the main electrical panel and the entry
to the furnace room. The furnace switch (service switch) should be
clearly labeled, and installed in a location where it is not likely to be
mistaken as being a light switch or similar control.
FIGURE 36 - INTEGRATED FURNACE IGNITION CONTROL
PARK
TERMINALS
ELECTRONIC
AIR CLEANER
POWER
HUMIDIFIER
120 VAC
MOLEX
120 VAC NEUTRAL
CONNECTIONS

14.2 120 FURNACE CONNECTION

The furnace is shipped fully wired except for the connections to the house wiring. The furnace power
connections are made in a junction box inside the blower compartment. The junction box contains a BLACK
wire to be connected with L1 (hot), a WHITE wire to be connected with L2, the Neutral, and a GREEN wire to
be connected to the ground.
NOTE
Use good quality wire nuts such as Marrette®
connectors, Ideal® wire nuts, etc.
If the junction box must be moved from it's original location to the other side of the unit.
1. Remove the appropriate plastic cap from the desired left or right side panel.
2. Secure power line connection into junction box, following above reference.
3. Fasten the junction box to the selected panel.
THIS FURNACE IS EQUIPPED WITH A BLOWER DOOR SAFETY SWITCH. DO NOT
DISABLE THIS SWITCH. FAILURE TO FOLLOW THIS WARNING CAN RESULT IN
W415-0919 / 10.12.10
5A FUSE
HEAT STAGING
JUMPER P5
!
ELECTRICAL SHOCK, PERSONAL INJURY, OR LOSS OF LIFE.
24 VAC MOLEX
ICM
INTERFACE
THERMOSTAT
TERMINALS
FAULT CODE
BUTTON
RED STATUS
LED
IMPORTANT:
USE COPPER CONDUCTORS ONLY.
WARNING
!
FIGURE 35 - ELECTRICAL CONNECTIONS /
MOLEX CONNECTOR