TOP EXIT HORIZONTAL TERMINATION

Simple venting configuration
(only one 90° elbow)
For vent configurations requiring more than one 90° elbow, the following formulas apply:
Formula 1: H
< V
T
T
Formula 2: H
+ V
T
T
Example 1:
V
= 3 FT (0.9m)
1
V
= 8 FT (2.4m)
2
V
= V
+ V
= 3FT (0.9m) + 8FT (2.4m) = 11FT (3.4m)
T
1
2
H
= 2.5 FT (0.8m)
1
H
= 2 FT (0.6m)
2
H
= H
+ H
= 2.5FT (0.8m) + 2FT (0.6m) = 4.5 FT (1.4m)
R
1
2
H
= .03 (three 90° elbows - 90°) = .03 (270° - 90°) = 5.4 FT (1.6m)
O
H
= H
+ H
= 4.5FT (1.4m) + 5.4FT (1.6m) = 9.9 FT (3m)
T
R
O
H
+ V
= 9.9FT (3m) + 11FT (3.4m) = 20.9FT (6.4m)
T
T
Formula 1:
H
9.9FT (3m) < 11FT (3.4m)
Formula 2:
H
20.9FT (6.4m) < 40 FT (12.2m)
Since both formulas are met, this vent configuration is acceptable.
See graph to determine the required vertical rise V
< 40 feet (12.2m)
< V
T
T
+ V
< 40 FT (12.2m)
T
T
(H
) < (V
)
T
T
40 (12.2)
39 (11.9)
30 (9.1)
REQUIRED
VERTICAL
20 (6.1)
RISE IN FEET
(METERS)V
T
10 (3.1)
0
2.5
(0.8)
HORIZONTAL VENT RUN PLUS OFFSET IN
40 (12.2)
39 (11.9)
30 (9.1)
REQUIRED
VERTICAL
20 (6.1)
RISE IN FEET
(METERS)V
T
10 (3.1)
0
2.5
(0.8)
HORIZONTAL VENT RUN PLUS OFFSET IN
The shaded area within the lines represents
for the required horizontal run H
T
5
7.5
10
12.5
15
(1.5)
(2.3)
(3.1)
(3.8)
(4.6)
FEET (METERS) H
T
5
7.5
10
12.5
15
(1.5)
(2.3)
(3.1)
(3.8)
(4.6)
FEET (METERS) H
T
acceptable values for H
and V
T
90°
V
2
90°
H
90°
1
V
1
16.2B
W415-0773 / F / 08.26.13
17
EN
.
T
GD36
17.5
20
(5.3)
(6.1)
BGD36
17.5
20
(5.3)
(6.1)
T
H
2