Denso QB30-SR User Manual page 127

2d code scanner (fixed type)
Table of Contents

Advertisement

Setting command
Data output timing
Non-scan code
Indirect mode
one-shot time
Trigger signal input
delay time
Signals output
ON duration width (Note
3)
Single output Delay time
(Note 3)
non-scan code
Scanning start command
Scanning end command
LED lighting on control
setting (Note1)
Decode time setting
(Note 1)
Note 1:
NG to indicate the scanning failure is output when decoding is unsuccessful during the setting time because
the scanner repeats the decode within readable code setting the upper limit of decode limit when scanning test
is performed. Effective only when Continuous reading mode A, Continuous reading mode B or auto sense
mode is selected.
Note 2:
0x20~0x7E excluding ASCII character can be registered.
Note 3
The setting is effective only for OK signal, NG signal, verification OK signal or verification NG signal.
Setting command
Output terminal 1 setting
Output terminal 1 setting
Transmitted command
(Change) WR11#n
(Confirmation) RD11
(Change) WR12#n
(Confirmation) RD12
(Change) WR15#nn
(Confirmation) RD15
(Change) WR16#nnn
(Confirmation) RD16
(Change) WR17#nnn
(Confirmation) RD17
(Change) WR18#nn
(Confirmation) RD18
(Change) WR19#hhhhhhh
(Confirmation) RD19
(Change) WR1A#hhhhhhh
(Confirmation) RD1A
(Change) WR1B#hhhhhhh
(Confirmation) RD1B
(Change) WR1C#nn
(Confirmation) RD1C
(Change) WR1D#nnn
(Confirmation) RD1D
Transmitted command
(Change) WR1E#n
(Confirmation) RD1E
(Change) WR1G#n
(Confirmation) RD1G
Response
OK
n=0: Synchronous
n
n=1: Asynchronous
OK
n=0: Enabled
n
n=1: Disabled
OK
nnn=010 - 999
nnn
(0.1 - 9.99 sec.)
OK
nnn=000 – 004 (No Delay time)
nnn=005~999 (5ms~999ms)
OK
nnn=001 - 255
nnn
(10 to 2550 ms)
OK
nn=00 – 99 (no Delay time)
nn= 01-99 (0.1 - 9.9 sec.)
OK
hhhhhhh=Non-scan code
hhhhhhh (Up to seven characters) (Not2)
OK
hhhhhhh=ON code setting
hhhhhhh (Up to seven characters)(Note 2)
OK
hhhhhhh=OFF code setting
hhhhhhh (Up to seven characters) (Note 2)
OK
n=0 :Always off
n
n=1 :Automatic
n=2 :Always on
OK
nnn=000: Disabled
(No decode time setting)
nnn
nnn=005 - 999 (0.05 - 9.99 sec.)
OK
n=0:Unused
n
n=1:OK signal output
n=2:NG signal output
n=3:Verification OK signal output
n=4:Verification NG signal output
n=5:READY signal output
OK
n=0:Unused
n
n=1:OK signal output
n=2:NG signal output
n=3:Verification OK signal output
n=4:Verification NG signal output
n=5:READY signal output
n=6:SHT signal output
116
Response

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qb30-su