Muratec MFX-3091 Advanced User's Manual page 86

Hide thumbs Also See for MFX-3091:
Table of Contents

Advertisement

List of the Device Setting Menu Items
E-mail
File Name
Setup
Template
From / Reply
To
Broadcast Destination
MDN Response
A/R Full Print
MCF Report
Timeout of MCF Report
Print Check Message
USB
File Name
Memory
Setup
Twain
Network TWAIN
Setup
*2
Port No.
PC Scan Mode
Timeout Setting
WSD
WSD Scan
Scan
Binding
Setup
Timeout Setting
Scanner
Execute
Calibration
Item
Edit Subject
Edit Body
From
E-mail Sender ID
Reply to
Factory
Default
(NULL)
Sets a file name of scanned images. Maxi-
mum 64 characters.
The following options can be set as the
default file name
#n: adding a serial number from 00000 to
99999
#d: adding the date of a file creation
(yymmddhhmmss)
(NULL)
Registers or edits standard e-mail subject
text. Maximum 80 characters.
(NULL)
Registers or edits standard e-mail body
text. Maximum 256 characters.
(NULL)
Sets the e-mail address which is given to the
[From] column. Maximum 80 characters.
(NULL)
Sets the sender name which is given to the
[From] column. Maximum 32 characters.
(NULL)
Sets the e-mail address which is given to the
[Reply to] column. Maximum 80 characters.
ON
Sets whether an e-mail address confirma-
tion screen is displayed before sending the
e-mail.
OFF
Sets whether to request the MDN (mes-
sage disposition notification) response.
OFF
Sets whether to print the transmission and
reception history reports automatically.
OFF
Sets whether to print a fax confirmation
after transmission.
15 minutes
Sets the timeout for printing a fax confir-
mation after transmission. If the setting
period of time is exceeded, the report is
automatically printed without the MDN
response.
OFF
Sets whether the error content is reported
when a transmission error occurs.
(NULL)
Sets the default setup for file names. Max-
imum 64 characters The following options
can be set as the default file name
#n: adding a serial number from 00000 to
99999
#d: adding the date of a file creation
(yymmddhhmmss).
ON
Sets whether to use the Network TWAIN.
9967
Sets the port number. Available range: 1
to 65535.
Simple Scan
Selects the default PC scan mode.
Mode
5 minutes
Sets the timeout duration.
Available range: 1 to 30 minutes.
Enable
Sets wether to use WSD Scan.
Long Edge Bind Sets the default binding position.
5 minutes
Sets the timeout duration.
Available range: 1 to 30 minutes.
Starts a scanner calibration.
- 86 -
Description
*1
:
*1
:

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents