  • Page 1 GXT2 - 3X1 Intelligent, High Frequency, Online UPS 10/15/20kVA USER MANUAL E1-20010329-C-1.0 Liebert Corporation...
  • Page 2 IMPORTANT INSTRUCTIONS FOR SAFE USE The UPS must be commissioned by a Liebert - approved engineer before it is put into service. Failure to observe this condition will invalidate any implied warranty . Do not apply power to this equipment before it has been commissioned by a Liebert - approved engineer.
  • Page 3 Do not place magnetic storage media on top of the unit as it can corrupt the data stored on them. Electromagnetic Compatibility WARNING This is a Class A UPS product. In a domestic environment this product may cause radio interference, in which case the user may be required to take additional measures.
  • Page 4: Table Of Contents

    Chapter 1 Introduction 1.1 Application 1.3 System Function Block 1.4 Features Chapter 2 Installation 2.1 Unpacking Inspection 2.2 Outline and Panel Description 2.2.1 Outline 2.2.2 Front Panel 2.2.3 Rear Panel 2.3 Installation 2.3.1 Important Note 2.3.2 Installation Procedure 2.4 Connection of External Batteries Chapter 3 Operation 3.1 Operating Mode 3.1.1 Normal Mode...
  • Page 5 3.2.6 LCD Panel Operation Chapter 4 Maintenance and Storage I. Battery Maintenance II. Keep Air Vent Unblocked III. UPS State Check IV. Function Inspection Chapter 5 Troubleshooting Appendix 1 LCD Panel Displays and Operation 1. Constitution of Display Panel 2. Function of display Panel 3.
  • Page 6: Chapter 1 Introduction

    Chapter 1 Product Introduction Chapter 1 Introduction 1.1 Application GXT2-3X1 Series UPS provides high quality AC power to your precision instrument. It can be applied in Computer Center , Network Management Center, Communication System, Automation Control System, precision instrument or other Critical Systems. 1.2 Classification "...
  • Page 7: Features

    bypass Breaker Backup Utility Utility Breaker Charger 1.4 Features GXT2-3X1 Series Three phase input/Single phase output 10kVA/15kVA /20kVA UPS is an advanced, intelligent, Online with Sinusoidal waveform output UPS system. The system adopts high-frequency double conversion topology structure with high input power factor, wide input voltage range, with the following Key features: UPS can operate with loss of input phases (up to 2 phases) Digital Signal Processing (DSP) Controlled.
  • Page 9: Chapter 2 Installation

    1. Unpack the packing box to move the UPS to position , be careful not to drop it as it is heavy. 2. In the event of product damage due to transportation, please notify Liebert or its authorized agent. 2.2 Outline and Panel Description 2.2.1 Outline...
  • Page 10 Chapter 2 Installation Air-inlet holes on Front Panel Utility Switch Bypass Switch Maintenance Switch Figure 2-2 Front view without panel Utility Battery Inverter Fault Bypass On/Silence Key LCD Display Enter Key Off Key Scroll Key Figure 2-3 LCD display Panel E1-20010329-C-1.0...
  • Page 11: Front Panel

    2.2.2 Front Panel Parts' Function Description Input Switch Bypass Switch Maintenance switch Front Panel air inlet hole LCD Panel and Description is in Appendix 1 in detail. 2.2.3 Rear Panel Parts' Function Description Input/output terminals Contact closure port Alarm relay port contact closure port Alarm Relay Port Ventilation holes...
  • Page 12: Installation

    Chapter 2 Installation Heat Dissipation and ventilation holes 2.3 Installation 2.3.1 Important Note 1. Please position the UPS on the flat ground/surface .. 2. The distance from the rear and side panels of the UPS to the wall or other equipment should be greater than 20cm, and the air inlets on the front panel and at the bottom of the UPS should be kept unobstructed to facilitate ventilation and heat dissipation.
  • Page 13: Installation Procedure

    Warning Classified according to European standard EN55022 , this is an A level UPS product. When it is used in family house, it may generate radio interference, user should take other measures in this condition. 2.3.2 Installation Procedure 1. Prior to any wire connection, please confirm that all the input and output circuit breakers are in “OFF”state;...
  • Page 14 Chapter 2 Installation Battery 1¡ ° + ¡ ± T erminal Battery1 + Terminal Battery 1¡ ° - ¡ ± T erminal Battrery1 - Terminal Battery 2¡ ° + ¡ ± T erminal Battery2 + Terminal Battery 2¡ ° - ¡ ± T erminal Battery2 - Terminal Figure 2-6(a)...
  • Page 15: Connection Of External Batteries

    5. To connect the UPS to servers for OS shutdown, please connect server's serial port to the contact closure port at the rear of the UPS. Follow installation procedure of OS shutdown software ( Liebert's multiLink ) for proper installation. 2.4 Connection of External Batteries 1.
  • Page 16 Chapter 2 Installation Battery Cabinet Breaker of Battery Cabinet Battery 2 Battery 1 Figure 2-10 connection of external batteries 5. Turn the switch on the battery cabinet to " ON " position. Note The battery connection and replacement should be done when the UPS is Completely switched OFF, if batteries are replaced while UPS is ON (hot - swappable ) pay attention not to reverse battery polarity.
  • Page 17 Backup UPS Output GND in Parallel Input GND in Parallel Input Neutral line in Parallel Input U phese line in Parallel Input V phase line in Parallel Input W phase line in parallel Figure 2-11(a) Wire connection for 10kVA Master-slave hot standby UPS E1-20010329-C-1.0 Chapter 2 Installation Master UPS...
  • Page 18 Chapter 2 Installation Figure 2-11(b) Wire connection for 15/20kVA Master-slave hot standby UPS Please refer to section 2.3.2 Installation Procedures( item 3 ) for wire connection requirement for 15/20kVA Master-slave hot standby UPS. Note Confirm the right connection of hot line and neutral line and proper earthing. For hot standby UPS, the batteries of master UPS and slave UPS must be connected separately.
  • Page 19: Chapter 3 Operation

    Chapter 3 Operation 3.1 Operating Mode 3.1.1 Normal Mode When the input Utility voltage and the load are within specifications, the load is supplied by inverter, which draws float-charges or equalize-charges the battery. When in Normal mode, the Utility indicator and inverter indicator on the LCD panel be green in colour ,as shown in Fig. 3-1.
  • Page 20: Battery Mode

    Chapter 3 Operation Note Under this mode, if the bypass power fails or bypass voltage exceed the bypass voltage windows. , the UPS will not provide power to the load. 3.1.3 Battery Mode When the UPS is in Normal mode, in the event of Utility failure or Utility voltage outside tolerances, the rectifier and charger will turn off , the battery begins to discharge and supply the load through inverter.
  • Page 21: Eco Mode

    Although the battery had been fully charged at factory before delivery, the transport and storage may result in loss of capacity , hence charging the battery for 8 hours is required before installing the UPS , so as to ensure adequate battery backup time. 3.1.4 ECO Mode ECO mode is the economic operation mode.
  • Page 22: Operation

    Chapter 3 Operation 3.2 Operation 3.2.1 Startup and Initialization After checking and making sure that the input and output cables are connected correctly, turn on the Utility switch and the bypass switch (for long backup time UPS, turn on the battery switch before closing the Utility switch). Then the system starts up, the internal fan begins to run, and the system begins to conduct self-test.
  • Page 23 Note If the previous shutdown was resulted from termination of battery discharge because of Utility failure, the automatic function will be activated when the Utility restores. 2, After the system is started up properly , apply the load gradually and monitor the load condition through LCD, as shown in Figure 3-8: 3, In the event of load exceeding the rated capacity of the UPS, of 105% load , the buzzer will beep every 0.5 second with corresponding load percentage indication .
  • Page 24: Manual Battery Self-Testing

    Chapter 3 Operation 1. Press and hold the ON/SILENCE button for about 1 second, after a beep and system self-test, the battery indicator and inverter indicator turns green, as shown in Fig. 3-9, and the buzzer beeps every 3 seconds, indicating the UPS is operating in Battery mode.
  • Page 25: Turn Off The Inverter

    Note After battery test, the battery state information will be refreshed. In the event of battery fault due to the battery not bang fully charged is detected during test, user may re-test the battery after fully charging it to confirm that the fault is removed. 3.2.4 Turn off the Inverter 1.
  • Page 27: Chapter 4 Maintenance And Storage

    If the battery backup time is found noticeably shortened, or when the UPS LCD displays "BATTERY FAIL", please contact the Liebert or its authoriged agent to confirm whether the battery needs to be replaced. Before replacement, please make sure that the specifications of the new batteries are correct.
  • Page 28: Keep Air Vent Unblocked

    Chapter 4 Maintenance and Storage Notice 1. Never short-circuit the battery terminals, which may result in fire. 2. Never open the battery, as the electrolyte is harmful to human body. In the event of inadvertent contact of electrolyte, immediately rinse it off with water and go to hospital for treatment .
  • Page 29: Chapter 5 Troubleshooting

    Chapter 5 Troubleshooting In the event of UPS fault, please check and remove the fault immediately following the methods described in the table below. If the fault persist , please contact Liebert or its authoriged agents. Sequence Phenomena Description No panel display and...
  • Page 30 Utility is normal, and then re-test the discharge time; B. The battery needs replacement, please contact the Liebert or its authoriged agent. . A. Check whether there is air flowing out from inside. B. Remove the objects...
  • Page 31: Appendix 1 Lcd Panel Displays And Operation

    Appendix 1 LCD Panel Displays and Operation LCD display interface is formed by LCD, LED and keys (see Appendix-Figure 1-1), it mainly finish the displaying and control of the following information: UPS basic parameter information, operating parameters information, alarm information, failure code information and function setup information.
  • Page 32 Chapter 1 Product Introduction 5 ) Battery indicator ( green ) :when the battery is discharging , it is on ; when it not discharging , the indicator is off. 2. Display Information 1 ) UPS basic parameter information Displays UPS' Model and present on/off state 2 )...
  • Page 33 (3) equalize function settings includes: (4) temperature Compensation settings includes: (5) Battery Capacity setup means the Ah of batteries used by UPS, for example: The battery capacity in two battery groups( each group contains 20 batteries) is all 100Ah, so the battery Capacity should be set up as 100Ah, includes: 24Ah No change 500Ah...
  • Page 34: Menu Operation

    0~255. (9) Frequency tracking range settings includes: User can select according to the power supply frequency requirement of load. 3. Function of Keys When the UPS is in off state, pressing this key 〈...
  • Page 35 Appendix-Figure 1-2 Keypad Operation 1. first level menu Pressing the scroll key can switch between " failure lookup", " operating parameters" and "function setup". Press the enter key to enter the menus of " operating parameters" ," failure lookup" or " function setup ". Note You can only enter “...
  • Page 36: Information Lcd-Displaying Priority

    Chapter 1 Product Introduction B) After entering " function setup " menu , function information which can be setup can be viewed and set by pressing the scroll key ; when the screen displays " Return to main menu", press enter key to return the main menu of " operating parameters ". C) After entering "...
  • Page 37: Relay Communication Mode

    Dry Contact Communication Mode Port Definition Pin2 : When the Utility fails, this pin will change from OPEN to CLOSE, it is OPEN in normal state; Pin5 : When the battery voltage is low, this pin will change from OPEN to CLOSE, it is OPEN in normal state; Pin6 : When +5V voltage has been applied for 1 second, the UPS will shutdown;...
  • Page 38 Appendix 2 Communication Port Description Connection alarm Signal failure Signal Bypass mode signal battery low Signal Shutdown Signal Connection of relays alarm Signal Relay failure Signal Relay Bypass mode Signal Relay battery low Signal Relay Shutdown Signal Relay Relay Contact Capacity 250VAC or 30VDC Pin .
  • Page 39: Appendix 2 Product Specification

    Appendix 2 Product Specification Capacity 10kVA Model GXT2-3X1 -0100L Input Input Mode Three-phase/four-line input rated voltage 400 Vac( line to line) voltage range 1. If the Phase to neutral voltage is in the range of 176-276Vac, the UPS can work normally with full load; 2.
  • Page 40 Appendix 3 Product Specification Capacity 10kVA Model GXT2-3X1 -0100L Bypass Voltage 120~253Vac ( non- ECO mode ) Efficiency in > 89% Normal Mode (100% Linear Load) Efficiency in > 88% battery mode (100% Linear Load) interrupt Utility Failure time Transferring <...
  • Page 41 Capacity 10kVA Model GXT2-3X1 -0100L Environment Condition Appendix 3 Product Specification 15kVA 20kVA GXT2-3X1 GXT2-3X1 -0200L -0150L E1-20010329-C-1.0...
  • Page 42: Appendix 3 Accessories

    Appendix 4 Accessories Appendix 3 Accessories Optional Product name battery cabinet Product Model Remark UF-B0100-38 20 38Ah batteries UF-B0100-65 20 65Ah batteries UF-B0100-100 20 100Ah batteries E1-669001-20010230-C-1.0...