Cleaning Equipment And Supplies; Cleaning And Sanitizing Procedure - Cornelius ID-90 Series Installation And Service Manual

Landmark ice dispensers
Table of Contents

Advertisement

Landmark Ice Dispenser Installation and Service Manual
C
E
LEANING
QUIPMENT AND
Recommended cleaner: A. C. Fergusson Company #3391 or any caustic-base (low sudsing, non-
perfumed, easily rinsed) detergent solution which provides a minimum 2% sodium hydroxide. The
solution should be prepared in accordance with the manufacturer's instructions. Solution temperature
should be between 90 to 110° F. Temperatures in excess of this can cause internal damage to the
dispensing valve components.
Recommended sanitizer: A. C. Fergusson Company SuperChlor or any sanitizer which provides a
minimum of 200 parts per million (200 milligrams per liter) of available chlorine. Solution temperature
should be between 90 to 110° F. Temperatures in excess of this can cause internal damage to the
dispensing valve components.
Containers for cleaner and sanitizer solutions
Clean, nonabrasive cloths
Bucket
Small Brush
C
S
LEANING AND
The ice bin should be thoroughly cleaned and sanitized at least once every month or as required by state
and local health departments.
WARNING - When using cleaning fluids or chemicals, rubber gloves and eye protection should be
worn.
1.
Disconnect electrical power to dispenser.
2.
Remove manual ice fill lid.
3.
Remove the ice chute.
4.
Remove dispense wheel by lifting out of bin.
5.
Using a soft brush, wash down the sides of the ice bin and the surface of the aluminum cold plate
and motor shaft with cleaning solution.
6.
Thoroughly rinse the cleaning solution from the ice bin.
7.
Using a soft brush and sanitizing solution, thoroughly brush all surfaces.
8.
Using a soft brush and cleaning solution, wipe all ice bin components and rinse thoroughly.
9.
Using a soft brush and sanitizing solution, and taking parts in order of replacement in bin,
thoroughly brush all parts and reinstall them in ice bin.
10.
Connect electrical power to dispenser and refill with ice.
NOTE: Static Breaker bar in the ice bin must be situated inside the right of the dispense door or
no ice will be dispensed.
Publication Number: 60418002
S
UPPLIES
P
ANITIZING
ROCEDURE
- 4 -
© 2004-2014, Cornelius Inc.

Advertisement

Table of Contents
loading

Table of Contents