Gree GWH(09)MA-K3DNA2B Service Manual page 48

Hide thumbs Also See for GWH(09)MA-K3DNA2B:
Table of Contents

Advertisement

Troubleshooting
Communication malfunction of
De-energize the unit and check if the
connecting wire of indoor and outdoor unit
and wiring of electric box are correct.
De-energize the unit. Check if the connecting wire
between outdoor mainbaord and filter plate is correct.
Check if there is power input between
neutral wire and live wire of outdoor unit.
Replace mainboard of outdoor unit
Does communication
all indoor units
Is wire connected
correctly
Yes
Is wire connected
correctly
Yes
Is connecting wire
damaged
No
Is there power
input?
Yes
resume normal
Yes
End
Connect wires
No
according to the
wiring diagram
Connect wires
No
according to the
wiring diagram
Yes
Replace the
connecting wire
No
Replace filter plate of
outdoor unit
No
Replace mainboard
of indoor unit
Note: The information above is for reference only.
Yes
Is malfunction
removed
No
Yes
Is malfunction
removed
No
Yes
Is malfunction
removed
No
Yes
Is malfunction
removed
No
46

Hide quick links:

Advertisement