Cooling Fan Temperature Chart - Jenn-Air JGS8750BD Series Service Manual

Jenn-air jgs8750bd series; jgs8850bd series; jgs8860bd series; jgs9900bd series slide-in gas range
Table of Contents

Advertisement

Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
Control Component
Switch membrane assembly
NOTE: To avoid equipment
damage, use caution when
checking electronic control
circuitry.
JGS8860BD*
Switch membrane assembly
NOTE: To avoid equipment
damage, use caution when
checking electronic control
circuitry.
JGS9900BD*
18
!
Test Procedure
Closed circuitry resistance
(defined as continuity): 2000 Max Ω
Pins 1 & 7 are shorted together for control
configuration purposes
Latch
Trace # 1
See Detail B
Closed circuitry resistance
(defined as continuity): 2000 Max Ω
Pins 1 & 10 are shorted together for control
configuration purposes
Latch
Trace # 1
See Detail B
COOLING FAN TEMPERATURES
MODE
FAN ON TEMP F (C)
Bake
350 (177)
Six (6) minute delay
Broil
after cycle started
Six (6) minute delay
Clean
after cycle started
WARNING
Pad
1
2
3
4
5
6
7
8
9
0
Cancel
Bake
Broil
Convect
Clean
Favorites
Detail B
Rapid Preheat
Warming Drawer
More Options
Setup
ATM 1
ATM 2
Back
Enter
Timer 1
Timer 2
Oven Light
Pad
1
2
3
4
5
6
7
8
9
0
Cancel
Bake
Broil
Convect
Clean
Favorites
Detail B
Rapid Preheat
Vent Fan
More Options
Setup
ATM 1
ATM 2
Back
Enter
Timer 1
Timer 2
Oven Light
FAN OFF TEMP F (C)
300 (149)
225 (107)
225 (107)
16026923
Results
Trace
Measurement
2 & 7
Continuity
2 & 8
Continuity
2 & 9
Continuity
2 & 10
Continuity
2 & 11
Continuity
2 & 12
Continuity
3 & 6
Continuity
3 & 7
Continuity
3 & 8
Continuity
2 & 6
Continuity
4 & 9
Continuity
4 & 10
Continuity
4 & 11
Continuity
5 & 9
Continuity
5 & 7
Continuity
4 & 12
Continuity
5 & 10
Continuity
5 & 11
Continuity
5 & 8
Continuity
5 & 6
Continuity
4 & 6
Continuity
4 & 7
Continuity
3 & 9
Continuity
3 & 10
Continuity
3 & 11
Continuity
3 & 12
Continuity
4 & 8
Continuity
Trace
Measurement
2 & 7
Continuity
2 & 8
Continuity
2 & 9
Continuity
2 & 10
Continuity
2 & 11
Continuity
2 & 12
Continuity
3 & 6
Continuity
3 & 7
Continuity
3 & 8
Continuity
2 & 6
Continuity
4 & 9
Continuity
4 & 10
Continuity
4 & 11
Continuity
5 & 9
Continuity
5 & 7
Continuity
4 & 12
Continuity
5 & 10
Continuity
5 & 11
Continuity
5 & 8
Continuity
5 & 6
Continuity
4 & 6
Continuity
4 & 7
Continuity
3 & 9
Continuity
3 & 10
Continuity
3 & 11
Continuity
3 & 12
Continuity
4 & 8
Continuity