JLG 600SJ Service And Maintenance Manual page 290

Table of Contents

Advertisement

SECTION 6 - JLG CONTROL SYSTEM
Table 6-5. Machine Configuration Programming Information Software Version P6.1 to Present
Configuration Label/
Digit
LOAD SENSOR:
17*
* Only visible if Load Sen-
sor Menu selection is not 0
and under certain market
selections.
* Certain market selections
will limit load sensor
options.
FUNCTION CUTOUT:
18*
* Only visible under certain
market selections.
* Certain market selections
will limit function cutout
options or alter default set-
ting.
GROUND ALARM:
19*
* Certain market selections
will alter default setting.
DRIVE:
20*
* Only visible under certain
model selections.
TEMPERATURE:
21*
* Certain market selections
will alter default setting.
6-44
Number
0
1 ON ROTATOR: Use the on-board load sensor for all models except those which use the
Leveling Platform Module.
1
4 UNDER PLATFORM: Use the EIM for load sensing.
0
NO: No drive cutout.
1
BOOM CUTOUT: Boom function cutout while driving above elevation.
2
DRIVE CUTOUT: Drive & steer cutout above elevation.
3
DRIVE CUT E&T: Drive & steer cutout above elevation and tilted.
0
NO: No ground alarm installed.
1
DRIVE: Travel alarm sounds when the drive function is active (Option).
2
DESCENT: Descent alarm sounds when lift down is active (Option).
3
MOTION: Motion alarm sounds when any function is active (Option).
0
4WD: Four wheel drive.
1
2WD: Two wheel drive.
2
2WD W/ 2-SPEED: Two wheel drive with 2-speed valve.
0
CELSIUS: Celsius unit selection.
1
FAHRENHEIT: Fahrenheit unit selection.
Description
– JLG Lift –
Default
Number
1
0
3
0
1
3121202

Advertisement

Table of Contents
loading

This manual is also suitable for:

600s660sj

Table of Contents