Electrical Connections - Trane *UH2B060A9V3VA Installer's Manual

Upflow / horizontal and downflow / horizontal, gas-fired, direct vent, 2-stage condensing furnaces with variable speed inducer
Hide thumbs Also See for *UH2B060A9V3VA:
Table of Contents

Advertisement

Installer's Guide

Electrical Connections

Make wiring connections to the unit as indicated on enclosed
wiring diagram. As with all gas appliances using electrical
power, this furnace shall be connected into a permanently live
electric circuit. It is recommended that furnace be provided
with a separate "circuit protection device" electric circuit. The
furnace must be electrically grounded in accordance with local
codes or in the absence of local codes with the National
Electrical Code, ANSI/NFPA 70 or CSA C22.1 Electrical Code,
if an external electrical source is utilized. The integrated
furnace control is polarity sensitive. The hot leg of the
120V power supply must be connected to the black power lead
as indicated on the wiring diagram.
Refer to the SERVICE FACTS literature and unit wiring
diagram attached to furnace.
FIELD WIRING DIAGRAM FOR VARIABLE SPEED 2 STAGE FURNACE
SEE
NOTE 6
SEE
NOTE 10
B/C
36
1 STAGE HEATING
USING A 1 STAGE HEATING THERMOSTAT
1. Be sure power agrees with equipment nameplates.
2. Low voltage (24 volt wiring) to be No. 18 A.W.G. min.
3. Grounding of equipment must comply with local codes.
4. Set thermostat heat anticipator per unit wiring diagram.
5. These leads provide 115V. power for connection of electronic
air cleaner and humidifier MAX. load 1.0 amps each.
W14
6. When a single stage heating thermostat without fan switch
is used, no wiring on "G" terminal is used.
7. W1 and W2 must be jumpered together for proper operation.
Second stage heat will begin based on IFC switch setting.
W14 JUMPER
8. Set dip switches with power off per installation instructions
SEE NOTE 11
to set airflow and indoor fan off delays.
9. Continuous fan airflow can be increased by adding this jumper.
10. This wire is only for thermostats requiring connection to
Y1/Ylo
transformer common terminal.
11. Optional humidistat is to be connected between R and BK. Factory installed jumper R
to BK on the circuit board must be cut if optional humidistat is used. The jumper must
also be cut when applying an airflow command signal to the BK input such as with the
SEE
variable speed single-zone and multi-zone system controllers. On single speed cooling
NOTE 9
only/non-heat pump systems, jumper Y to O for proper operation of the delay profiles
and the humidistat. For two compressor or two speed systems, jumper YLo to O.
FIELD ADDED JUMPER
W1 TO W2.
SEE FURNACE WIRING DIAGRAM
FOR 2ND STAGE TIMING.
TO 115 V 1 PH.,
60 HZ., POWER
SUPPLY PER
B/C
LOCAL CODES
HUM SEE
NOTE 5
EAC SEE
NOTE 5
NO COOLING
Figure 60
From Dwg. B342027 Rev. 1
18-CD26D1-10

Hide quick links: