Air Cleaner With Air Intake From The Blower Housing/Filter Replacement - Tecumseh SPECTRA 37 Service And Repair Manual

Table of Contents

Advertisement

For Discount Tecumseh Engine Parts Call 606-678-9623 or 606-561-4983
9. AIR CLEANER WITH AIR INTAKE FROM
THE BLOWER HOUSING
Fig. 14
A.
Filter Cover
B.
Screws
C.
Filter Element
D.
Foam Gasket
E.
Foam Support
F.
Base
G.
Breather Gas Recirculation Filter
Proceed as follows:
1. Remove filter body by unscrewing the two screws.
Do not remove screws from the filter body.
2. Inspect the following areas for dirt accumulation: a,
e, f.
Remove the foam air filter and the breather gas
recirculation foam. If the foams are dirty or clogged
they must be replaced. Refer to "Filter Replacement".
3. Check the gasket inside the filter body. Replace if it
is damaged or deformed.
FILTER REPLACEMENT
To remove the foams from the body and from the base,
follow instruction 1 in the preceding section; Then
proceed as follows:
1. Clean inside the body, the foam support and the filter
base.
2. Saturate the new foam with two table spoons (approx.
20 ml) of clean engine oil. Squeeze (do not twist) to
evenly distribute the oil and remove excess oil. Do
not oil the new breather gas recirculation foam.
3. Fit the new foam into the body making sure it is
correctly seated into the body. Ensure the foam gasket
(d) is fitted correctly in the body. Install the new
breather gas recirculation foam into its proper seat
on the base.
4. Position the foam support on the filter base. The
bevelled part of the support must point towards the
air intake. The fins of the support must face up.
5. Position the body and tighten the two screws securely.
DO NOT OVERTIGHTEN.