Specifications Of Electrical Parts - Toshiba RAS-B16N3KV2-E Service Manual

Split type
Hide thumbs Also See for RAS-B16N3KV2-E:
Table of Contents

Advertisement

6. SPECIFICATIONS OF ELECTRICAL PARTS

6-1. Indoor Unit
No.
Parts name
1
Fan motor (for indoor)
2
Room temp. sensor (TA-sensor)
3
Heat exchanger temp. sensor (TC-sensor)
4
Louver motor
6-2. Outdoor Unit
No.
Parts name
1
Reactor
2
Outdoor fan motor
3
Suction temp. sensor (TS sensor)
4
Discharge temp. sensor (TD sensor)
5
Outside air temp. sensor (TO sensor)
6
Heat exchanger temp. sensor (TE sensor)
7
Terminal block (5P)
8
Compressor
9
COIL FOR P.M.V.
10
Coil for 4-way valve
Type
MF-340-30-3
AC 240V, 20W
( - )
10kΩ at 25°C
( - )
10kΩ at 25°C
MSBPC20F04
Output (Rated) 1W, 16 poles, DC12V
Type
CH-57 (2 Pcs)
L = 10mH, 16A
ICF-140-43-4R
DC140V, 43W
(Inverter attached)
10kΩ (25°C)
(Inverter attached)
62kΩ (20°C)
(Inverter attached)
10kΩ (25°C)
(Inverter attached)
10kΩ (25°C)
JX0-5B
20A, AC250V
DA131S1B-31FZ
3-phases 4-poles 1100W
CAM-MD12TCTH-5
DC12V
STF
AC220-240V